Description
High-Density Centralized Control: The 8-Channel 10A KNX Switch Actuator
In modern commercial building automation, maximizing the efficiency of electrical distribution boards is a critical objective for engineers and system integrators. The SIXINSMART 8-Channel 10A KNX Switch Actuator (G-NR8.10.1) delivers an optimal balance of high-density channel capacity and robust electrical switching. Housed in a standardized 8SU DIN-rail enclosure, this multi-fold relay controller consolidates eight independent circuits into a single, manageable KNX node. It is designed to bridge heavy-duty AC loads with the intelligent KNX/EIB bus, providing a reliable, long-lasting switching backbone for office towers, industrial facilities, and hospitality projects.
Universal Load Capability: From Resistive to Capacitive
Electrical networks in B2B environments are highly complex, often comprising a mix of lighting ballasts, motors, and standard resistive loads. The G-NR8.10.1 is specifically engineered to handle this diversity. Each of its 8 channels utilizes a high-quality standalone mechanical relay rated for 10A at 230VAC@50Hz, allowing the entire actuator to manage a maximum total current of 80A. These relays are rigorously tested and certified as suitable for Resistive, Capacitive, and Inductive Loads. This means the actuator can effortlessly absorb the inrush currents generated by modern LED power supplies or fluorescent ballasts, preventing contact welding and ensuring an exceptional mechanical life of 1,000,000 operations.
100% KNX Bus-Powered Architecture
A major pain point in cabinet assembly is the routing of auxiliary power. The SIXINSMART 8-Channel Actuator features a highly efficient internal power topology that draws its operational current directly from the KNX/EIB bus (consuming <150mW and <5mA). By eliminating the need for an external 24VDC or 230VAC auxiliary power supply for the device’s internal electronics, contractors can significantly reduce wiring time, save valuable DIN-rail space, and remove a potential point of hardware failure from the distribution board.
Advanced Onboard Logic: Decentralizing Building Automation
To ensure zero-latency execution and reduce data traffic across the main KNX backbone, the G-NR8.10.1 is equipped with a sophisticated local microprocessor. Integrators can program extensive Scene Group Control architectures (managing up to 16 scene groups, with each supporting 64 scenes) and dynamic Sequence Control configurations (5 sequence functions, supporting 16 steps each). The built-in Logical Functions (AND, OR, XOR, Logic Gates) and Threshold Functions (High/Low Threshold, Hysteresis) enable the actuator to independently evaluate data from external KNX presence detectors or lux sensors, triggering localized automation without relying on a central server.
Dual-Discipline Application: PWM Heating Control
This switch actuator is not limited to lighting control; it serves as a dual-discipline building automation node. Through ETS5 or ETS6 configuration, specific channels can be assigned a dedicated Heating Function. The actuator outputs a precise PWM (Pulse Width Modulation, 1-bit/1-byte) control signal, allowing it to directly manage proportional thermoelectric valves for radiators and underfloor heating manifolds. This dual-use capability enables integrators to consolidate HVAC and lighting control into a single physical unit, significantly optimizing project hardware costs.
Proactive System Diagnostics and Fail-Safe Mechanics
Facility managers require absolute transparency into their electrical infrastructure. The actuator provides continuous network updates via built-in Control Functions, including Channel Status Responses, Time-Delayed Transmissions, and periodic Heartbeat Packet Transmissions. To safeguard the facility against power grid instability, highly customizable Power-Up Recovery parameters dictate the exact state each relay should assume when power is restored, preventing hazardous inrush surges. Additionally, hardcoded Time Functions (Time-Delay Control, Flashing Control, and Stairwell Lighting Functions) offer rapid, out-of-the-box programming for corridors and secure areas.
Verbatim Technical Parameters (G-NR8.10.1 Specification)
The following engineering parameters are extracted verbatim from the official technical datasheet, ensuring exact specifications for system designers, electrical contractors, and B2B procurement professionals.
| Category | Parameter Name | G-NR8.10.1 |
|---|---|---|
| Basic Parameters |
KNX Bus Voltage | 30VDC |
| KNX Bus Current | <5mA | |
| KNX Bus Power Consumption |
<150mW | |
| Number of Switching Output Channels |
8 | |
| Output Tytle | Standalone Relay | |
| Output Switching Performance |
voltage | 230VAC@50Hz |
| load current | 10A | |
| The maximum total current allowed by the entire actuator |
80A | |
| Output Life | Mechanical Life | 1000000ops |
| Electrical Life | 100000ops | |
| Operation and Display |
Programming Button | Set Physical |
| Manual Button/LED Indicator |
Manual Control and Indication | |
| Environment | Ta/Operation Tempe | -5~+45°C |
| Ts/Storage Temp | -20~+60°C | |
| Operating Humi | 10~95% RH Condensation-Free | |
| Safety&EMC | Safety Standards | IEC 60669-2-1:2021, IEC 60669-1:2017, IEC 63044-3:2017, EN 50491-2:2010 + A1:2020, EN IEC 63044-3:2018, EN IEC 63044-5-1:2019, EN IEC 63044-5-2:2019, EN IEC 60669-2-1:2022 |
| Electromagnetic Compatibility Emission |
IEC 63044-3:2017,EN IEC 63044-5-1:2019;EN IEC 63044-5-2:2019, EN IEC 63044-3:2018, EN IEC 63044-5-1:2019, EN IEC 63044-5-2:2019 |
|
| Electromagnetic Compatibility Immunity |
IEC 63044-3:2017, EN IEC 63044-5-1:2019; EN IEC 63044-5-2:2019, EN IEC 63044-3:2018, EN IEC 63044-5-1:2019, EN IEC 63044-5-2:2019 |
|
| Withstand Voltage | KNX Between Ports and Relay Terminals: 2KVAC | |
| Other | Screw Terminal | Stranded Wire, 0.5-4.0mm² Solid Wire, 0.5-2.5mm² |
| KNX Bus Terminal | 0.8mm , Solid Wire | |
| Dimension | 144*90*64mm | |
| Face Width | 8SU | |
| Install | 35mm DIN Rail Mounting |
Remark: Unless otherwise specified, all specifications are measured at 230VAC input, rated load, and an ambient temperature of 25°C. Provide the test report issued by a certification body.
System Integrator Insights: 8-Channel KNX Switch Actuators
Q1: What are the engineering advantages of using an 8-channel actuator over two 4-channel units?
A: Specifying an 8-channel actuator like the G-NR8.10.1 significantly reduces hardware overhead and simplifies programming. By consolidating 8 independent relays into a single KNX physical address, integrators reduce the number of bus nodes, lowering overall bus traffic. Furthermore, the 8SU footprint maximizes DIN-rail density in distribution enclosures, reducing cabinet size and lowering labor costs during installation.
Q2: Can the G-NR8.10.1 safely handle modern LED lighting circuits?
A: Yes. The device is officially rated for Capacitive and Inductive loads alongside standard Resistive loads. LED power supplies typically generate high capacitive inrush currents that can fuse standard relay contacts. Our 10A standalone relays are rigorously tested to absorb these transient spikes, ensuring high electrical longevity (100,000 operations) even when switching complex commercial lighting grids.
Q3: How does the PWM Heating Function work on a standard switch actuator?
A: The intelligent firmware allows any of the 8 relay channels to be repurposed via ETS software to output a Pulse Width Modulation (PWM) signal. This 1-bit or 1-byte control accurately pulses the relay to drive thermal actuators on underfloor heating manifolds or radiator valves. This transforms a standard lighting controller into a high-precision HVAC thermostat component, offering immense flexibility.
Q4: Does the actuator require an external 230V or 24V power supply to operate its microprocessor?
A: No external auxiliary power is required. The G-NR8.10.1 features a highly optimized, bus-powered architecture. It draws all necessary operational power directly from the KNX/EIB bus connection (consuming less than 150mW and <5mA). This eliminates the cost and wiring of secondary power modules within the electrical cabinet.
Q5: Can electrical contractors test the load wiring without a KNX programmer on-site?
A: Yes, manual operation is fully supported. The faceplate includes dedicated tactile buttons and LED status indicators for each of the 8 channels. Electricians can physically toggle the relays to test AC load connections and verify circuit stability immediately upon installation, entirely independent of the ETS software commissioning process.