Description
Professional Industrial KNX 8-Fold 20A Switching Solution
For large-scale commercial and industrial building automation, reliability and power density are non-negotiable. The SIXINSMART SW0008.2010 KNX 8-Fold 20A Switch Actuator stands as a premier choice for global B2B procurement, offering high-current switching capacity integrated with sophisticated current monitoring technologies. This device is specifically engineered to handle the rigorous demands of modern infrastructure, from large lighting grids to heavy-duty motor control.
Compliant with the EN 60 715 installation standard, the SW0008.2010 is designed for standard 35mm DIN rail mounting. Its modular design allows for rapid deployment in electrical distribution boards. By connecting directly to the KNX system through the standard bus terminal, it eliminates the need for auxiliary power supplies, drastically reducing installation complexity and energy overhead for large-scale projects.
Comprehensive Monitoring & Safety Features
Unlike standard relay modules, the SW0008.2010 is equipped with precision current detection. This allows system integrators to implement real-time load monitoring, identifying potential failures before they occur. The system supports overload alarms and automatic protective cut-offs, providing an essential layer of protection for expensive commercial equipment. Maintenance teams can also utilize the manual forced switch levers on the device face for rapid troubleshooting without needing access to the ETS software.
Expanded Product Features & Technical Advantages
1. Heavy-Duty Switching & Load Protection
Each of the 8 channels supports a rated current of 20A. This high-capacity design is essential for handling inductive and capacitive loads, such as large lighting groups where inrush current is a critical factor. The mechanical endurance of 10⁶ operations ensures long-term ROI for facility owners.
2. Advanced Current Sensing & Monitoring
Equipped with high-precision current detection, the SW0008.2010 enables real-time monitoring of electrical consumption. System integrators can configure overload alarms and protective cut-offs, providing proactive safety measures against short circuits or appliance failure.
3. Manual Control & Visual Diagnostics
The front panel includes manual forced switch levers and LED status indicators for every channel. This physical interface is vital for electricians during the initial commissioning phase or when emergency manual override is required without a computer or ETS access.
4. Sophisticated Logic & Scene Control
Beyond simple switching, the unit supports AND / OR logic operations. Each channel can participate in up to 8 different scenes, and the staircase lighting function includes a safety warning feature to prevent occupants from being left in sudden darkness.
Ordering Information & Series Selection
Precision selection of the correct actuator fold and current rating is critical for project success. Below is the official ordering matrix for the SIXINSMART Switch Actuator series, detailing the hardware configuration for each specific model.
| Order model | name | Current detection | Manual lever | LED |
|---|---|---|---|---|
| SW0001. 1611 | 1-fold 16A Switch actuator | Yes | Yes | No |
| SW0001.2010 | 1-fold 20A Switch actuator | Yes | Yes | No |
| SW0002. 1001 | 2-fold 10A Switch actuator | No | No | No |
| SW0004. 1001 | 4-fold 10A Switch actuator | No | No | Yes |
| SW0004. 1611 | 4-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0004. 2010 | 4-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0006. 1001 | 6-fold 10A Switch actuator | No | No | Yes |
| SW0006. 1611 | 6-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0006. 2010 | 6-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0008. 1001 | 8-fold 10A Switch actuator | No | No | Yes |
| SW0008. 1611 | 8-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0008. 2010 | 8-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0012. 1001 | 12-fold 10A Switch actuator | No | No | Yes |
| SW0012. 1611 | 12-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0012. 2010 | 12-fold 20A Switch actuator | Yes | Yes | Yes |
Technical Parameters
The following electrical specifications are verified as per the official SW0008.2010 technical dossier.
| KNX Input | KNX voltage | DC 21V~31V |
| KNX Current | <12mA | |
| KNX Power consumption | <360mW | |
| Wiring terminal | KNX cable | Standard KNX twisted pair cables |
| Torque | 0.8Nm | |
| Range of wiring diameter | 0.2-6mm² | |
| Output characteristic | Max Switching Current | 20A |
| Max switching power | 5000VA | |
| Mechanical Endurance | 10⁶ | |
| Current detection | Yes (Standard) | |
| Operation temperature | -25°C ~ +55°C | |
| Installation | Installed on a 35 mm guide rail | |
| Appearance | Grey white, PVC material | |
| Authentication | KNX, CE | |
Project Integration FAQ: KNX 8-Fold 20A Switch Actuator
Is the current detection on the SW0008.2010 granular enough for energy management systems?
Yes. The SW0008.2010 provides real-time current sensing for each fold. This data can be utilized by smart building energy management systems (EMS) to monitor specific channel loads, set overload alarm thresholds, and implement automated protective cut-offs to prevent system-wide electrical failures.
Which ETS version is required for commissioning the 8-fold switch actuator?
Our hardware is designed for future-proof engineering. As of April 2026, the SW0008.2010 is fully compatible with the latest ETS6.4.1. Integrators should use the SWI03 database for both 6-fold and 8-fold actuator configurations to ensure all current detection and logic features are accessible.
Can the 20A relay handle capacitive lighting loads?
Absolutely. The 20A rating provides a significant safety margin for commercial LED lighting groups which often have high inrush currents. With a maximum switching power of 5000VA per channel, it is robust enough for capacitive and inductive loads common in commercial environments.
Does this switch actuator support fail-safe status query?
Yes. Each channel supports status value query replies. Additionally, you can configure the output actions for bus power-up and power-down scenarios, as well as device blocking modes, ensuring your building automation system remains in a safe, predictable state regardless of network status.