KNX 1-Fold 16A Switch Actuator (SW0001.1611): Industrial Intelligence for Modern BMS
The SIXINSMART SW0001.1611 is a high-performance, single-channel 16A switch actuator engineered for the most demanding professional smart building automation systems. Designed for system integrators and architectural engineers, this device provides precision control over electrical loads with an uncompromising focus on reliability, decentralized logic, and real-time load monitoring.
Comprehensive Product Overview
This manual provides you with detailed information on the SIXINSMART Switch Actuators series products, including installation, programming, and how to use switch actuators. This series of products complies with the EN 60 715 installation standard and is installed on a 35mm guide rail. The SIXINSMART switch actuator series is available in 1, 2, 4, 6, 8, and 12 folds, offering maximum flexibility for distribution board design.
The switch actuator is connected to the KNX system through the KNX bus terminal and does not require an additional power supply to control the load. The allocation of physical addresses and the setting of parameters require the use of ETS software. As of April 2026, our firmware fully supports ETS 6.4.1, utilizing the SWI02 database for 1-fold, 2-fold, and 4-fold switch actuators.
Advanced Functional Logic & Features
- Switch Function: Precise control of load devices with customizable delay setting for the on/off action.
- Staircase Lighting: Integrated staircase lighting function with essential warning signals for public safety compliance.
- Current Detection: Real-time monitoring, overload alarm, and protective cut-off functionality.
- Logical Operations: Built-in AND, OR gate functions allow for complex conditional automation at the device level.
- Manual Emergency Override: Physical manual forced switch allows for circuit testing and manual control during maintenance.
- Scene Management: Each channel has 8 scenes available for complex architectural lighting atmospheres.
- Status Query: General control function with status value query reply for real-time BMS feedback.
- Fail-Safe Configuration: Adjustable output actions during bus power on/off and device blocking/non-blocking states.
2 Ordering Information (Complete 15-Model Matrix)
| Order model | Name | Current detection | Manual lever | LED |
|---|---|---|---|---|
| SW0001. 1611 | 1-fold 16A Switch actuator | Yes | Yes | No |
| SW0001. 2010 | 1-fold 20A Switch actuator | Yes | Yes | No |
| SW0002. 1001 | 2-fold 10A Switch actuator | No | No | No |
| SW0004. 1001 | 4-fold 10A Switch actuator | No | No | Yes |
| SW0004. 1611 | 4-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0004. 2010 | 4-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0006. 1001 | 6-fold 10A Switch actuator | No | No | Yes |
| SW0006. 1611 | 6-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0006. 2010 | 6-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0008. 1001 | 8-fold 10A Switch actuator | No | No | Yes |
| SW0008. 1611 | 8-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0008. 2010 | 8-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0012. 1001 | 12-fold 10A Switch actuator | No | No | Yes |
| SW0012. 1611 | 12-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0012. 2010 | 12-fold 20A Switch actuator | Yes | Yes | Yes |
3 Technical Parameters
| Parameter Name | SW0001. 1611 | |
|---|---|---|
| KNX Input | KNX voltage | DC 21V~31V |
| KNX Current | <12mA | |
| KNX Power consumption | <360mW | |
| Wiring terminal | KNX cable | Require the use of KNX standards twisted pair cables |
| Torque | 0.8Nm | |
| Range of wiring diameter | 0.2-6mm² | |
| Output characteristic | Max Switching Current | 16A |
| Max switching power | 4000VA | |
| Mechanical Endurance | 10&sup6; | |
| Operation temperature | -25°C ~ +55°C | |
| Installation | Installed on a 35 mm guide rail | |
| Appearance | Grey white, PVC material | |
| Authentication | KNX, CE | |
Professional Engineering FAQ for KNX Actuators
Q1: How does the current detection and overload protection enhance system safety?
In high-load B2B environments, real-time current detection is paramount. The SW0001.1611 monitors the load of each channel, providing immediate status feedback and overload alarms. If current exceeds safe thresholds, the protective cut-off functionality prevents equipment damage and electrical fire hazards, ensuring long-term infrastructure stability.
Q2: What logic gates are integrated into the hardware?
The actuator features built-in AND and OR logical operations. This allows for conditional automation sequences to be processed directly at the actuator level—for example, lighting only activates if both an occupancy sensor AND a timer signal are active—reducing KNX bus traffic and central CPU load.
Q3: Is the SW0001.1611 compatible with the latest ETS6 software?
As of April 2026, our switch actuator series is fully verified and compatible with ETS 6.4.1. It uses the SWI02 database for physical address allocation and parameter setting, ensuring that system integrators can deploy our products using the most up-to-date engineering tools.
Q4: Does the actuator require an external power supply?
No. The module is fully bus-powered. It connects to the KNX/EIB system through the standard bus terminal and draws less than 12mA, significantly simplifying installation in industrial and commercial distribution boards.
Q5: How does the manual override function during a bus failure?
Our 16A and 20A models are equipped with a physical manual forced switch. This allows onsite engineering teams to manually control the load status during commissioning or in scenarios where bus communication is unavailable, providing an essential fail-safe for building maintenance.