Description
Advanced KNX 1-Fold 20A Switch Actuator (SW0001.2010): Heavy-Duty Infrastructure Control
The SIXINSMART SW0001.2010 represents the pinnacle of high-capacity KNX relay engineering. This manual provides you with detailed information on the SIXINSMART Switch Actuators series products, including installation, programming, and how to use switch actuators. Designed strictly for professional B2B system integrators and commercial electrical contractors, this 1-fold 20A actuator delivers uncompromising power handling combined with sophisticated edge-logic capabilities.
This series of products complies with the EN 60 715 installation standard and is installed on a 35mm guide rail. The switch actuator is connected to the KNX system through the KNX bus terminal and does not require an additional power supply to control the load. The allocation of physical addresses and the setting of parameters require the use of ETS software. As verified by our engineering team in April 2026, the firmware operates flawlessly on the ETS 6.4.1 platform, utilizing the SWI02 database for 1-fold, 2-fold, and 4-fold switch actuators.
Core Automation Functions & Logic Processing
To meet the rigorous demands of modern Building Management Systems (BMS), the SW0001.2010 is equipped with a comprehensive suite of onboard automation functions, reducing the processing load on central KNX controllers:
- High-Capacity Switch Function: Capable of managing demanding loads with programmable delay settings for both the on and off action, essential for staggered motor startups or heavy lighting arrays.
- Commercial Staircase Lighting: Features a dedicated staircase lighting function equipped with a pre-warning function (such as dimming or flickering) to alert occupants before the lights extinguish, ensuring safety code compliance.
- Current Detection Function (Predictive Maintenance): A critical feature for 20A applications. It provides real-time monitoring, overload alarm notifications, and automated protective cut-off protocols to prevent catastrophic hardware failure.
- Architectural Scene Function: Each channel has 8 scenes available for use, allowing integrators to program complex environmental lighting transitions with a single group address command.
- Integrated Logical Operations: Onboard AND, OR gate functions allow the actuator to process environmental variables (e.g., occupancy AND time-of-day) locally.
- Manual Forced Switch & Status Query: Features a general control function, status value query, and a physical manual forced switch (a premium feature excluding 10A specification switch actuators).
- Deterministic Fail-Safe Configuration: The output actions during bus power on/off and device blocking/non-blocking can be set, guaranteeing that the building returns to a known, safe state following power fluctuations.
2 Ordering Information (Complete Series Matrix)
Below is the complete 15-model matrix for the SIXINSMART switch actuator series. Please ensure the SW0001.2010 matches your project’s requirement for 20A capacity, current detection, and manual lever presence.
| Order model | Name | Current detection | Manual lever | LED |
|---|---|---|---|---|
| SW0001. 1611 | 1-fold 16A Switch actuator | Yes | Yes | No |
| SW0001. 2010 | 1-fold 20A Switch actuator | Yes | Yes | No |
| SW0002. 1001 | 2-fold 10A Switch actuator | No | No | No |
| SW0004. 1001 | 4-fold 10A Switch actuator | No | No | Yes |
| SW0004. 1611 | 4-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0004. 2010 | 4-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0006. 1001 | 6-fold 10A Switch actuator | No | No | Yes |
| SW0006. 1611 | 6-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0006. 2010 | 6-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0008. 1001 | 8-fold 10A Switch actuator | No | No | Yes |
| SW0008. 1611 | 8-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0008. 2010 | 8-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0012. 1001 | 12-fold 10A Switch actuator | No | No | Yes |
| SW0012. 1611 | 12-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0012. 2010 | 12-fold 20A Switch actuator | Yes | Yes | Yes |
3 Technical Parameters
| Parameter Name | SW0001.2010 | |
|---|---|---|
| KNX Input | KNX voltage | DC 21V~31V |
| KNX Current | <12mA | |
| KNX Power consumption | <360mW | |
| Wiring terminal | KNX cable | Require the use of KNX standards twisted pair cables that comply with KNX standards |
| Torque / Range of wiring diameter | 0.8Nm / 0.2-6mm² | |
| Output characteristic | Max Switching Current | 20A |
| Max switching power | 5000VA | |
| Mechanical Endurance | 10^6 | |
| Current detection | 50mA ~ 20A,Accuracy of 5%, less than 50mA is susceptible to interference and may result in larger errors | |
| Operation temperature | -25°C ~ +55°C | |
| Installation | Installed on a 35 mm guide rail | |
| Appearance | Grey white, PVC material | |
| Authentication | KNX、CE | |
KNX Heavy-Duty Actuator: Engineering FAQ
Q1: How does the current detection feature benefit large-scale B2B installations?
For commercial integrators, maintaining uptime is critical. The SW0001.2010 provides real-time monitoring of 20A loads. It enables predictive maintenance by issuing an overload alarm and triggering a protective cut-off if electrical parameters exceed safe thresholds. This protects expensive motors, HVAC components, and lighting arrays from permanent damage.
Q2: Can electrical contractors manually control the relay during the commissioning phase?
Yes. Unlike standard 10A switch actuators, the SW0001.2010 includes a physical manual forced switch directly on the hardware. This is an essential B2B feature that allows onsite engineers to toggle the 20A circuit manually for testing, even before the KNX bus is fully programmed or during network downtime.
Q3: Is the SW0001.2010 compatible with the latest ETS 6.4.1 programming software?
Absolutely. We ensure long-term compatibility for our global integrators. As of April 2026, the device is fully tested and certified for the ETS 6.4.1 environment. Engineers must use the SWI02 database for the allocation of physical addresses and the setting of parameters.
Q4: Does the actuator require an external 24V or 230V power supply to operate its internal logic?
No. The switch actuator is highly efficient. It is connected to the KNX system through the KNX bus terminal and does not require an additional power supply to control the load. It draws less than 12mA directly from the DC 21V~31V bus, saving critical distribution board space and reducing thermal buildup.
Q5: Can this KNX heavy-duty relay handle localized automation without a master logic controller?
Yes. The device features integrated logical operations, specifically AND, OR gate functions. This allows the SW0001.2010 to process multiple environmental conditions (for instance, turning on a 20A industrial fan only if a temperature threshold AND occupancy sensor are both triggered) locally, thereby reducing KNX bus traffic.