Premium KNX 12-Fold 16A Switch Actuator | SW0012.1611 DIN Rail Relay Controller with Current Detection & ETS6.4.1 Support

Uncompromising Channel Density & Smart Load Management

The SIXINSMART SW0012.1611 KNX 12-Fold 16A Switch Actuator is engineered to revolutionize commercial distribution boards. Tailored for global system integrators, this device consolidates extensive switching capabilities and real-time electrical diagnostics into a single, high-efficiency DIN rail footprint, ensuring ultimate reliability for complex building automation topologies.

  • ✔High-Density 12-Channel Architecture: Optimize your cabinet layouts significantly. This 12-fold module (L=216mm) dramatically reduces required DIN rail space compared to deploying multiple smaller units, thereby lowering hardware procurement and installation costs for large-scale enterprise deployments.
  • ✔16A Commercial-Grade Switching: Built to withstand rigorous daily operations. Each output provides a dependable 16A rated current with a maximum switching power of 4000VA, making it perfectly suited for standard commercial lighting circuits, fan coils, and general-purpose facility switching.
  • ✔Integrated Current Detection: Step up your facility management game. Includes native real-time current monitoring (50mA~20A), smart overload alarms, and protective cut-offs, providing critical data for predictive maintenance and protecting infrastructure from electrical faults.
  • ✔Manual Forced Switch Integration: Ensures fail-safe commissioning. Features physical manual override levers and dedicated LED status indicators for all 12 channels. On-site engineers can immediately toggle circuits during installation or emergencies without requiring KNX bus power or ETS access.
  • ✔Verified ETS6 Compatibility: Engineered for the future of smart infrastructure. Fully authenticated by CE and KNX, the SW0012.1611 is strictly tested to guarantee 100% compatibility with the latest ETS6.4.1 framework (certified as of April 2026) using the specialized SWI04 database.
  • ✔Bus-Powered Efficiency: Designed for maximum operational stability. The internal components are powered entirely by the KNX bus terminal (<360mW). The actuator definitively does not require any additional auxiliary power supply to control the load, eliminating unnecessary wiring complexities.
Download KNX Switch Actuator Technical Manual Download KNX Switch Actuator User Manual

Description

The Ultimate 12-Channel KNX Control Node for Smart Facilities

When executing large-scale commercial building automation, maximizing control density without sacrificing reliability is the key to project success. The SIXINSMART KNX 12-Fold 16A Switch Actuator (Model: SW0012.1611) provides system integrators with an expansive control platform, specifically designed for the opening and closing control of 12 distinct load devices. By integrating twelve 16A relays into a single, cohesive module, this actuator empowers electrical contractors to significantly reduce distribution cabinet size while managing substantial lighting and HVAC loads.

Strictly compliant with the EN 60 715 installation standard, the SW0012.1611 is built for rapid deployment on standard 35mm guide rails. A core advantage of this high-density unit is its bus-powered topology. The actuator connects to the KNX network exclusively through the KNX bus terminal and definitively does not require an additional power supply to control the load. This eliminates the need for bulky auxiliary power modules, reduces thermal generation in the panel, and simplifies the overall electrical schematic.

1. Intelligent Diagnostics & Decentralized Automation

To fully leverage the hardware capabilities, the allocation of physical addresses and the precise setting of operational parameters mandate the use of ETS software. For the massive 12-fold variant, engineers will deploy the SWI04 database. This specialized software environment provides access to a comprehensive suite of digital functions essential for proactive facility management:

  • Active Current Detection: The SW0012.1611 is equipped with sophisticated current monitoring circuitry. It tracks energy usage across all 12 channels, provides status value query replies, and triggers overload alarms and protective cut-offs, safeguarding the building’s infrastructure from electrical faults.
  • Programmable Switch Delays: System architects can configure targeted delays for the setting of the on/off action. This cascading power-up sequence is vital when activating 12 circuits simultaneously, effectively preventing massive inrush currents from tripping the facility’s main breakers.
  • Extensive Scene Flexibility: Each of the 12 individual channels has 8 scenes available for use. This allows lighting designers to seamlessly orchestrate complex, multi-zone environmental transitions—from an “all-off” security state to dynamic hospitality lighting—with a single KNX command.
  • Embedded Logical Operations: The actuator natively handles AND & OR gate functions. It can evaluate multiple sensor inputs (e.g., motion and ambient light) locally, initiating load responses without congesting the main KNX bus with continuous communication traffic.
  • Safety-Oriented Staircase Lighting: Features a robust staircase lighting function that incorporates an advanced warning feature. The system can be set to dim or pulse the lighting before full shut-off, ensuring safe passage in commercial stairwells and complying with stringent safety codes.
  • Resilient Fail-Safe Configurations: Integrators have absolute control over system recovery. The output actions during bus power on/off states, as well as device blocking/non-blocking modes, can be strictly defined, ensuring the entire 12-channel array enters a predictable, secure state during power grid fluctuations.

2. Complete Ordering Information (SW0012.1611)

The SIXINSMART switch actuator series is highly versatile, offering 1, 2, 4, 6, 8, and 12 folds to meet precise project requirements. Please refer to the official ordering matrix below to accurately specify the SW0012.1611 for your procurement planning.

Order model name Current detection Manual lever LED
SW0001. 1611 1-fold 16A Switch actuator Yes Yes No
SW0001.2010 1-fold 20A Switch actuator Yes Yes No
SW0002. 1001

SW0004. 1001

2-fold 10A Switch actuator

4-fold 10A Switch actuator

No

No

No

No

No

Yes

SW0004. 1611 4-fold 16A Switch actuator Yes Yes Yes
SW0004. 2010 4-fold 20A Switch actuator Yes Yes Yes
SW0006. 1001 6-fold 10A Switch actuator No No Yes
SW0006. 1611 6-fold 16A Switch actuator Yes Yes Yes
SW0006. 2010 6-fold 20A Switch actuator Yes Yes Yes
SW0008. 1001 8-fold 10A Switch actuator No No Yes
SW0008. 1611 8-fold 16A Switch actuator Yes Yes Yes
SW0008. 2010 8-fold 20A Switch actuator Yes Yes Yes
SW0012. 1001 12-fold 10A Switch actuator No No Yes
SW0012. 1611 12-fold 16A Switch actuator Yes Yes Yes
SW0012. 2010 12-fold 20A Switch actuator Yes Yes Yes

3. Technical Parameters (SW0012.1611)

The definitive engineering parameters provided below assure the SW0012.1611’s capacity to operate faultlessly within demanding commercial infrastructure.

Parameter Category SW0012.1611 Specification
KNX Input KNX voltage DC 21V~31V
KNX Current <12mA
KNX Power consumption <360mW
Wiring terminal KNX cable Require the use of KNX standards twisted pair cables that comply with
Torque 0.8Nm
Range of wiring diameter 0.2-6mm²
Output characteristic Max Switching Current 16A
Max switching power 4000VA
Mechanical Endurance 106
Current detection 50mA~20A, Accuracy of 5%, less than 50mA is susceptible to interference and may result in larger errors
Operation temperature -25°C ~ +55°C
Installation Installed on a 35 mm guide rail
Appearance Grey white, PVC material
Authentication KNX, CE

Strategic Procurement FAQ for Electrical Contractors & Integrators

1. Why is the 12-fold 16A actuator preferred for commercial lighting projects?

Space optimization is crucial in modern electrical design. The SW0012.1611 maximizes channel density, consolidating the control of 12 distinct circuits into a single DIN rail footprint. Furthermore, the robust 16A relay rating provides a substantial safety margin for managing the inrush currents generated by high-power commercial LED drivers, outperforming standard 10A modules.

2. How does the integrated current detection interact with a Central BMS?

The SW0012.1611 actively measures current across a 50mA to 20A range. It can be programmed to send real-time data or triggered alerts to your Building Management System (BMS). This empowers facility managers to monitor energy consumption accurately, enact automated load shedding during peak tariffs, and receive immediate overload alarms to prevent system failure.

3. Which exact ETS database file must be used for configuring the 12-channel model?

Given its high channel density and extensive feature set, the 12-fold switch actuator requires the use of the specialized SWI04 database. This database ensures engineers have complete access to all 12 channels’ logic gates, scene controls, and current monitoring thresholds during commissioning.

4. Is the SW0012.1611 confirmed to operate with the latest ETS programming tools?

Absolutely. As a CE and KNX certified device, forward compatibility is guaranteed. The SW0012.1611 and its corresponding SWI04 database have been rigorously tested and verified to be fully compatible with the latest ETS6.4.1 software release, as documented up to April 2026.

5. Are auxiliary 24V or mains power modules needed to operate the 12 relays?

No. The highly efficient internal circuitry of the SW0012.1611 is completely bus-powered. It draws all its required operational power (<12mA) directly via the KNX bus terminal. It expressly does not require any additional auxiliary power supply to control the 12 load lines, significantly simplifying cabinet construction.

6. What practical value do the manual forced switches offer during installation?

The integrated manual forced switches are critical physical overrides. During the rough-in phase—before the KNX bus is active or the ETS software is programmed—contractors can utilize these mechanical levers to manually test the circuit wiring, verify load operation, and ensure electrical integrity without delay.