Description
Advanced KNX 4-Fold 16A Switch Actuator for Commercial Infrastructure
The SIXINSMART SW0004.1611 is a robust 4-fold 16A KNX switch actuator specifically engineered for the demanding requirements of modern commercial buildings, hospitals, and industrial facilities. As a core component for smart building system integrators, this device offers precise control over electrical loads while providing critical feedback data through its advanced monitoring features.
Designed for reliability, the SW0004.1611 complies with the EN 60 715 standard for 35mm DIN rail mounting. It operates seamlessly within the KNX ecosystem, requiring no additional power supply as it draws its operating energy directly from the bus terminal. This efficiency, combined with its high-load switching capability, makes it suitable for large-scale automation projects.
Power Monitoring and Protective Logic
Distinguishing itself from standard actuators, the SW0004.1611 features integrated current detection and real-time monitoring. The actuator can trigger overload alarms and execute protective cut-offs before equipment damage occurs. Combined with logic operations (AND, OR gate functions), integrators can design feedback logic for HVAC and lighting systems without external logic modules.
Ordering Information & Specification Matrix
Refer to the following ordering matrix for the SIXINSMART switch actuator series. The SW0004.1611 row is highlighted.
Technical Parameters (Model: SW0004.1611)
Frequently Asked Questions from System Integrators
Q1: How does the current detection functionality assist in project maintenance?
The integrated current detection in the SW0004.1611 allows real-time monitoring of each load channel. Engineering teams can set thresholds to receive alerts before a failure occurs, supporting preventive maintenance in lighting and other switched-load applications.
Q2: Is the SW0004.1611 compatible with the latest ETS6 software environment?
As of April 2026, the SW0004.1611 is compatible with ETS 6.4.1. The SWI02 database can be used for physical address allocation and parameter configuration during commissioning.
Q3: Can the manual forced switches be used during a KNX bus communication failure?
The physical manual levers provide local override for the output circuits, allowing onsite electrical contractors or maintenance staff to operate the relays locally when required.
Q4: What logic gate operations are supported by this switch actuator?
The actuator supports AND and OR logical operations, allowing selected KNX conditions to be processed locally before a switching action is executed.
Q5: Does this device require an auxiliary 220V power supply to operate?
No. The switch actuator electronics are powered by the KNX bus (21–31V DC) and the listed KNX power consumption is below 360mW.