Description
SIXINSMART KNX 4-Fold 16A Switch Actuator (SW0004.1601): Streamlined Automation for Commercial Infrastructure
For system integrators and electrical engineering contractors managing complex Building Management Systems (BMS), balancing project budgets with uncompromised hardware reliability is a daily challenge. The SIXINSMART SW0004.1601 is a specialized 4-channel 16A switch actuator developed exactly for this purpose. This manual provides you with detailed information on the SIXINSMART Switch Actuators series products, including installation, programming, and how to use switch actuators.
This series of products complies with the EN 60 715 installation standard and is installed on a 35mm guide rail. SIXINSMART switch actuator series, available in 1, 2, 4, 6, 8, and 12 folds. The switch actuator is connected to the KNX system through the KNX bus terminal and does not require additional power supply to control the load. The allocation of physical addresses and the setting of parameters require the use of ETS software. Utilizing the SWI02 database (which is used for 1-fold, 2-fold, and 4-fold switch actuators), this module is fully verified for compatibility with the latest ETS 6.4.1 architecture as of April 2026.
Core Engineering Functions & Decentralized Logic
The SW0004.1601 is designed to handle demanding lighting arrays, localized HVAC components, and heavy-duty resistive loads up to 4000VA per channel. While this specific custom variant excludes current detection to optimize bulk procurement costs, it retains all premium automation features:
- Switch Function & Delay Dynamics: Can delay setting the on/off action. This prevents high inrush currents from tripping main breakers by staggering the activation of multiple high-load circuits.
- Staircase Lighting Function: Integrated with a warning function. This feature temporarily dims or flashes the lighting circuit before total shutdown, a critical requirement for stairway and corridor safety in commercial real estate.
- Scene Functionality: Each channel has 8 scenes available for use. Integrators can bind these channels to master group addresses, enabling complex architectural environment transformations instantly.
- Hardware-Level Logical Operations: AND, OR gate functions are embedded within the firmware. This allows the actuator to evaluate multiple inputs (e.g., ambient light levels AND room occupancy) locally, triggering the 16A relays without relying on a central KNX logic module.
- General Control & Manual Forced Switch: General control function, status value query, and a physical manual forced switch are fully integrated. The manual levers allow onsite technicians to physically actuate the relays during initial cabinet wiring or emergencies.
- Deterministic Fail-Safe States: The output actions during bus power on/off and device blocking/non-blocking can be set. This guarantees the building infrastructure defaults to a secure, pre-determined state during power grid fluctuations.
2. Ordering Information
The following table outlines the standard SIXINSMART ordering matrix. Note: The SW0004.1601 is a specialized project variant of the 4-fold 16A series, maintaining the manual lever but omitting current detection for cost-efficiency.
| Order model | Name | Current detection | Manual lever | LED |
|---|---|---|---|---|
| SW0001. 1611 | 1-fold 16A Switch actuator | Yes | Yes | No |
| SW0001. 2010 | 1-fold 20A Switch actuator | Yes | Yes | No |
| SW0002. 1001 | 2-fold 10A Switch actuator | No | No | No |
| SW0004. 1001 | 4-fold 10A Switch actuator | No | No | Yes |
| SW0004. 1611 | 4-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0004. 2010 | 4-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0006. 1001 | 6-fold 10A Switch actuator | No | No | Yes |
| SW0006. 1611 | 6-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0006. 2010 | 6-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0008. 1001 | 8-fold 10A Switch actuator | No | No | Yes |
| SW0008. 1611 | 8-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0008. 2010 | 8-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0012. 1001 | 12-fold 10A Switch actuator | No | No | Yes |
| SW0012. 1611 | 12-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0012. 2010 | 12-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0004. 1601 | 4-fold 16A Switch actuator | No | Yes | Yes |
| SW0006. 1601 | 6-fold 16A Switch actuator | No | Yes | Yes |
| SW0008. 1601 | 8-fold 16A Switch actuator | No | Yes | Yes |
| SW0012. 1601 | 12-fold 16A Switch actuator | No | Yes | Yes |
3. Technical Parameters
The following hardware parameters guarantee the mechanical and electrical endurance of the SW00XX series. The SW0004.1601 aligns structurally with the SW00XX.1611 specification column below, excluding the current detection module.
| Parameter Name | SW0004. 1601 | |
|---|---|---|
| KNX Input | KNX voltage | DC 21V~31V |
| KNX Current | <12mA | |
| KNX Power consumption | <360mW | |
| Wiring terminal | KNX cable | Require the use of KNX standards twisted pair cables that comply with |
| Torque / Range of wiring diameter | 0.8Nm / 0.2-6mm² | |
| Output characteristic | Max Switching Current | 16A |
| Max switching power | 4000VA | |
| Mechanical Endurance | 10^6; | |
| Operation temperature | -25°C ~ +55°C | |
| Installation | Installed on a 35 mm guide rail | |
| Appearance | Grey white, PVC material | |
| Authentication | KNX、CE | |
System Integrator FAQ: KNX 4-Fold 16A Actuator
Q1: Why does the SW0004.1601 model exclude the current detection function?
The SW0004.1601 is specifically customized for large-scale engineering projects where high-capacity 16A switching and manual hardware control are mandatory, but individual circuit power monitoring is handled elsewhere (or not required). By excluding the current detection function, we significantly reduce the unit cost, allowing wholesale B2B buyers to scale their distribution panels much more affordably without losing KNX reliability.
Q2: Can I manually control the 4 channels without ETS programming?
Yes. A major advantage of this KNX 4 fold 16A switch actuator is the inclusion of a physical manual forced switch for each channel. Electrical contractors can manually toggle the relays on the physical unit to test lighting and HVAC circuits immediately after wiring, even before the KNX bus is fully commissioned.
Q3: Is the SW0004.1601 fully certified and compatible with ETS 6.4.1?
Absolutely. SIXINSMART ensures forward compatibility. As of April 2026, the device firmware is fully certified for use within the ETS 6.4.1 environment. Integrators simply utilize our standard SWI02 database to allocate physical addresses, set delay parameters, and configure scene logic seamlessly.
Q4: How do the embedded logic operations (AND/OR gates) improve my BMS?
By utilizing the onboard logical operations (AND, OR gate functions), the actuator can independently process localized automation rules. Instead of routing sensor data back to a central server, the relay can decide to trigger a 16A load locally based on multiple inputs. This greatly reduces data traffic on the KNX bus and improves the response time of the smart building.
Q5: What are the power requirements for the internal module logic?
The entire logic and relay actuation mechanism is powered directly by the KNX system through the KNX bus terminal (DC 21V~31V). It consumes less than 360mW (<12mA) and does not require an additional 230V or 24V power supply to control the load, saving valuable DIN rail space and wiring labor.