Description
Architectural Grade Dimming: KNX 6 Fold 1-10V Actuator (DM0106.0031)
In the global B2B procurement of building management systems, lighting accounts for the majority of the electrical footprint. The SIXIN KNX 6 Fold 1-10V Dimming Actuator is a premier DIN-rail mounted controller engineered explicitly for advanced LED driver management. Operating on the ubiquitous 1-10V standard, this module provides 6 independent channels of signal regulation alongside 6 synchronized 16A mechanical relays.
The distinction of the 1-10V standard is critical for commercial lighting designers: it establishes a defined 1% baseline for the lowest dimming state, ensuring LEDs do not drop out or flicker. To achieve a complete blackout, the DM0106.0031 leverages its integrated manual-lever relays to physically disconnect the AC mains from the driver. This dual-action approach—analog signal for ultra-smooth fading combined with an electromechanical hard-cut for the OFF state—represents the industry gold standard for energy efficiency and hardware protection.
1 Technical Parameters
* Note: The following specifications strictly align with the official manufacturer parameters for the series base model as documented.
| Category | Parameter | DM0106.0031 |
|---|---|---|
| KNX bus voltage | DC 21V-31V | |
| KNX bus current | < 3mA | |
| KNX features | KNX bus | A KNX-compliant twisted-pair cable (0.8mm diameter) is required to connect the EIB/KNX bus terminals |
| 24V power supply characteristics | Supply current | 130mA(all 6 channels output 10V/30mA) |
| 0~10V output feature | Number of channels | 6 |
| Maximum output current per channel | 30mA | |
| Maximum number of connected drives per channel (2mA/ drive) | 15 | |
| Load characteristics | Load terminal connection terminal | A torque of 0.8Nm is required to terminate the load Wire range 0.2 to 6mm² (AWG 10 to 24) |
| Load maximum switching current | 16A (with separate relays per channel) | |
| Mechanical durability | 106 times | |
| Manipulation and display | Programming buttons and corresponding indicator lights | When assigning physical address and downloading configuration parameters, press the programming button, and the orange LED indicator lights up |
| Operation status indication | Orange leds indicate relay action | |
| Operating temperature range | -25°C~+45°C | |
| Mechanical parameters | Volume | 108*90*63mm |
| Weight | 360g | |
| Installation | 35mm U-guide rail | |
| Appearance | Gray, PVC panels |
Logic Programming & System Intelligence
The actuator connects to the global KNX system strictly via the standard KNX bus terminals, isolating the data layer from the physical lighting layer. All physical address assignments and parameter configurations are downloaded via the ETS software. Global system integrators can deploy the following algorithmic behaviors independently per fold:
- Absolute & Relative Dimming: Direct percentage recall via 1-byte values (Absolute) or smooth up/down scaling via 4-bit commands (Relative), ensuring total compatibility with any KNX touch panel or SCADA interface.
- Dimming Interval & Velocity Mechanics: Open/close speed and brightness transition values can be rigidly defined. This guarantees that large banks of LED fixtures fade uniformly without staggered visual disruptions.
- Scene Management (8-Fold Capacity): Deep memory allocation permits each channel to participate in up to 8 unique architectural scenes, executing complex ambient transitions via a single group address trigger.
- Stair Lighting Function: Dedicated logic for transient spaces. The actuator can automatically delay the off action after a set time, fading the lights slowly to warn occupants before a complete blackout.
- General Control, Auto & Blocking: Seamless integration with daylight harvesting sensors (Automatic function) and security overrides (Blocking function) to lock channels during emergency egress protocols or maintenance windows.
Global Integrator FAQ: 1-10V Dimming Infrastructure
Q1: Why requires the DM0106.0031 an additional 24V power supply?
A: In professional KNX deployments, galvanic isolation is a strict requirement to protect the data bus. The KNX 6 Fold 1-10V Dimming Actuator draws less than 3mA from the KNX line for its internal microprocessor. However, to generate clean, high-fidelity 1-10V control signals capable of sinking/sourcing 30mA per channel across long cable runs, it utilizes an auxiliary 24VDC power supply. This ensures the dimming signal remains immune to voltage drops and electromagnetic interference.
Q2: What is the maximum load capacity for the LED drivers on each circuit?
A: Electrical contractors must dimension the load correctly. The signal output is rated at a maximum of 30mA per channel. Assuming an industry-standard consumption of 2mA per LED driver on the signal line, a single channel can reliably control up to 15 connected drivers. Simultaneously, the robust internal relays handle a maximum switching current of 16A (AC) for the actual mains power distribution.
Q3: How does the manual lever assist in the commissioning of B2B projects?
A: During the “shell and core” phase of commercial construction, the KNX network is often offline. Our actuator is equipped with six 16A relays featuring manual dial levers. This allows on-site electricians to manually flip the relays to the ON position, powering the LED drivers to test the physical mains wiring and lighting arrays long before the system integrator programs the ETS software.
Q4: Is the product software compliant with the latest ETS 6.4.1 release?
A: Absolutely. Procurement managers and lead engineers can specify this product with certainty. Based on rigorous software QA completed in April 2026, the DM0106.0031 is fully certified and compatible with the ETS 6.4.1 environment. It guarantees rapid parameter downloading and seamless group address mapping without requiring legacy workarounds.
Q5: What are the specific installation requirements for the load terminals?
A: Adhering to the EN 60 715 installation standard, the device mounts to a 35mm U-guide rail. For the high-voltage load connections, installers must use a wire range of 0.2 to 6mm² (AWG 10 to 24). Crucially, to prevent micro-arcing and ensure long-term thermal stability, a precise tightening torque of 0.8Nm is required for terminating the load.