Description
Precision Relay Control for Commercial Building Automation
In the highly competitive landscape of smart building integration, selecting the right hardware means balancing performance, reliability, and project budget. The SIXINSMART KNX 6 Fold 10A Switch Actuator (Model: SW0006.1001) is explicitly designed for the opening and closing control of 6-way load equipment where the rated current per output is 10A. This device provides electrical contractors and wholesale distributors with a rock-solid, streamlined relay controller that handles standard commercial loads flawlessly without the added cost of unnecessary industrial features.
This comprehensive actuator series complies fully with the EN 60 715 installation standard, ensuring seamless mounting on standard 35mm DIN guide rails across global markets. A distinct installation advantage is its bus-powered design: the switch actuator interfaces with the KNX system solely through the KNX bus terminal and does not require any additional power supply to control the load. This reduces cabinet clutter, speeds up installation time, and minimizes points of failure in complex electrical topologies.
1. Comprehensive Functional Programming
The allocation of physical addresses and the precise setting of parameters require the use of standard ETS software. For the 6-fold SW0006.1001 model, integrators will utilize the SWI03 database. Through this interface, a wide array of intelligent functions can be deployed:
- Dynamic Switch Function: Allows engineers to delay the setting of the on/off action. This is critical for staging the power-up sequence of lighting zones to prevent breaker tripping from simultaneous inrush currents.
- Staircase Lighting & Safety: Features an integrated staircase lighting timer complete with a pre-warning function. The system will alert users (e.g., via a brief flicker) before the lights extinguish, an essential compliance feature for public building safety codes.
- Extensive Scene Management: Each individual channel provides 8 distinct scenes available for use. This allows a single actuator to participate in multiple complex environmental presets, such as transitioning a conference room from a “Presentation” state to a “Meeting” state.
- Embedded Logical Operations: The actuator natively processes AND / OR gate functions. It can evaluate multiple sensor inputs directly, executing commands locally without burdening the main KNX bus with excess traffic.
- General Control & Status Query: Supports master control commands (General On/Off) and status value query replies, keeping the Central Building Management System (BMS) perfectly synchronized with the hardware state.
- Fail-Safe State Definitions: System architects can explicitly define the output actions during bus power on/off events, as well as device blocking/non-blocking scenarios, ensuring the facility enters a predictable, safe state during power disruptions.
2. Ordering Information
The SIXINSMART switch actuator series is available in 1, 2, 4, 6, 8, and 12 folds to meet the exact channel density requirements of any project. Please refer to the table below to distinguish the SW0006.1001 from other variants in our lineup.
| Order model | name | Current detection | Manual lever | LED |
|---|---|---|---|---|
| SW0001. 1611 | 1-fold 16A Switch actuator | Yes | Yes | No |
| SW0001.2010 | 1-fold 20A Switch actuator | Yes | Yes | No |
| SW0002. 1001
SW0004. 1001 |
2-fold 10A Switch actuator
4-fold 10A Switch actuator |
No
No |
No
No |
No
Yes |
| SW0004. 1611 | 4-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0004. 2010 | 4-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0006. 1001 | 6-fold 10A Switch actuator | No | No | Yes |
| SW0006. 1611 | 6-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0006. 2010 | 6-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0008. 1001 | 8-fold 10A Switch actuator | No | No | Yes |
| SW0008. 1611 | 8-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0008. 2010 | 8-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0012. 1001 | 12-fold 10A Switch actuator | No | No | Yes |
| SW0012. 1611 | 12-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0012. 2010 | 12-fold 20A Switch actuator | Yes | Yes | Yes |
3. Technical Parameters (SW0006.1001)
The following technical parameters apply strictly to the 10A switch actuator series, ensuring accurate electrical planning for your distribution panels.
| Parameter Category | SW0006.1001 Specification | |
| KNX Input | KNX voltage | DC 21V~31V |
| KNX Current | <12mA | |
| KNX Power consumption | <360mW | |
| Wiring terminal | KNX cable | Require the use of KNX standards twisted pair cables that comply with |
| Torque | 0.8Nm | |
| Range of wiring diameter | 0.2-6mm² | |
| Output characteristic | Max Switching Current | 10A |
| Max switching power | 2500VA | |
| Mechanical Endurance | $10^{6}$ | |
| Current detection | (Not applicable for 10A models) | |
| Operation temperature | -25°C ~ +55°C | |
| Installation | Installed on a 35 mm guide rail | |
| Appearance | Grey white, PVC material | |
| Authentication | KNX、CE | |
Professional FAQ for KNX Integrators & Wholesalers
1. Why does the SW0006.1001 model omit current detection and manual forced switches?
The 10A switch actuator series (including the SW0006.1001) is purposefully engineered to provide a highly cost-effective solution for standard load switching. By excluding current detection and manual levers, we reduce the component cost and physical complexity. This makes it the ideal volume-purchase choice for massive B2B deployments where real-time current monitoring on standard lighting circuits is unnecessary.
2. Which ETS database should my engineers use to commission this 6-fold actuator?
For allocating physical addresses and setting parameters on the KNX 6 Fold 10A Switch Actuator, your technical team must use the SWI03 database. This specific database is optimized for both our 6-fold and 8-fold switch actuators, ensuring stable operation and full access to logic, scene, and staircase lighting functions.
3. Is the SW0006.1001 fully compatible with the latest ETS6 software framework?
Yes. We continuously update and test our product catalog against standard global KNX protocols. As of April 2026, the SW0006.1001 is rigorously tested and 100% compatible with the latest ETS6.4.1 software releases, guaranteeing future-proof integration for modern smart building projects.
4. Will I need to install a separate DIN-rail power supply to operate the relays?
No. A major installation advantage of this product series is that it draws its operational power entirely from the KNX bus feed (DC 21V~31V, drawing <12mA). It strictly does not require an additional auxiliary power supply to switch the load, freeing up valuable DIN rail space and lowering your project’s overall hardware cost.
5. Does this model provide visual status indication if it lacks manual switches?
Yes. Although the 10A specification excludes the mechanical manual forced switch lever, the SW0006.1001 is fully equipped with LED status indicators for each of the 6 folds. This allows maintenance personnel to visually verify the ON/OFF state of each channel directly at the distribution board.