Description
SIXINSMART KNX 6-Fold 16A Switch Actuator (SW0006.1601): High-Density Control for Commercial BMS
In modern commercial building management systems (BMS), optimizing distribution cabinet space while maintaining high load capacity is a primary concern for system integrators. The SIXINSMART SW0006.1601 is a specialized 6-channel 16A switch actuator engineered to address this exact requirement. This manual provides you with detailed information on the SIXINSMART Switch Actuators series products, including installation, programming, and how to use switch actuators.
This series of products complies with the EN 60 715 installation standard and is installed on a 35mm guide rail. SIXINSMART switch actuator series, available in 1, 2, 4, 6, 8, and 12 folds. The switch actuator is connected to the KNX system through the KNX bus terminal and does not require additional power supply to control the load.
The allocation of physical addresses and the setting of parameters require the use of ETS software. Specifically, the SWI03 database is used for 6-fold switch actuators and 8-fold switch actuators. As of April 2026, our engineering department has certified this module to be fully compatible with the latest ETS 6.4.1 environment, ensuring robust and secure programming for international tenders.
Functional Intelligence & Logic Processing
The SW0006.1601 variant is strategically designed for wholesale procurement. By excluding the current detection function, it provides a highly cost-effective solution for projects that demand 16A switching and manual override, without the added expense of individual circuit monitoring. Its core functionalities include:
- Switch Function with Delay: Can delay setting the on/off action. This is crucial for staggering the startup of high-inrush 16A loads, preventing main breaker trips in large facilities.
- Staircase Lighting Function: Built-in staircase timers with warning function. The lights will dim or flash prior to turning off, ensuring compliance with commercial egress and safety standards.
- Hardware Logical Operations: Integrated AND, OR gate functions. The actuator processes environmental conditions locally, drastically reducing data traffic across the KNX network.
- Scene Functionality: Each channel has 8 scenes available for use, providing immense flexibility for boardroom, auditorium, or open-office architectural lighting.
- Manual Forced Switch: General control function, status value query, and a physical manual forced switch are standard. This allows onsite electricians to actuate the relays during cabinet testing without ETS software.
- Deterministic Fail-Safe Configuration: The output actions during bus power on/off and device blocking/non-blocking can be set. This ensures the building defaults to a known safe state during power grid anomalies.
2. Ordering Information (Complete Series Portfolio)
To assist procurement teams and engineering consultants, the following table details the complete SIXINSMART switch actuator portfolio as referenced in our technical manual. Note: The SW0006.1601 is an optimized sub-variant derived from the 1611 architecture, offering manual levers without current detection.
| Order model | Name | Current detection | Manual lever | LED |
|---|---|---|---|---|
| SW0001. 1611 | 1-fold 16A Switch actuator | Yes | Yes | No |
| SW0001. 2010 | 1-fold 20A Switch actuator | Yes | Yes | No |
| SW0002. 1001 | 2-fold 10A Switch actuator | No | No | No |
| SW0004. 1001 | 4-fold 10A Switch actuator | No | No | Yes |
| SW0004. 1611 | 4-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0004. 2010 | 4-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0006. 1001 | 6-fold 10A Switch actuator | No | No | Yes |
| SW0006. 1611 | 6-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0006. 2010 | 6-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0008. 1001 | 8-fold 10A Switch actuator | No | No | Yes |
| SW0008. 1611 | 8-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0008. 2010 | 8-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0012. 1001 | 12-fold 10A Switch actuator | No | No | Yes |
| SW0012. 1611 | 12-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0012. 2010 | 12-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0004. 1601 | 4-fold 16A Switch actuator | No | Yes | Yes |
| SW0006. 1601 | 6-fold 16A Switch actuator | No | Yes | Yes |
| SW0008. 1601 | 8-fold 16A Switch actuator | No | Yes | Yes |
| SW0012. 1601 | 12-fold 16A Switch actuator | No | Yes | Yes |
3. Technical Parameters
The parameters below represent the mechanical and electrical specifications extracted directly from our technical documentation. The SW0006.1601 hardware aligns mechanically with the 16A and 20A structures but excludes the current detection circuitry for B2B wholesale optimization.
| Parameter Name | SW0006. 1601 | |
|---|---|---|
| KNX Input | KNX voltage | DC 21V~31V |
| KNX Current | <12mA | |
| KNX Power consumption | <360mW | |
| Wiring terminal | KNX cable | Require the use of KNX standards twisted pair cables that comply with |
| Torque / Range of wiring diameter | 0.8Nm / 0.2-6mm² | |
| Output characteristic | Max Switching Current | 16A |
| Max switching power | 4000VA | |
| Mechanical Endurance | 10^6 | |
| Operation temperature | -25°C ~ +55°C | |
| Installation | Installed on a 35 mm guide rail | |
| Appearance | Grey white, PVC material | |
| Authentication | KNX、CE | |
Global Integrator FAQ: 6-Fold 16A KNX Actuator
Q1: Why is the SW0006.1601 specified without current detection?
The SW0006.1601 is an optimized engineering variant. For many large-scale commercial lighting projects, wholesale buyers require robust 16A switching capacity and manual testing levers, but do not need individual circuit power monitoring. Removing the current detection module drastically lowers unit costs, allowing contractors to win highly competitive bids.
Q2: Which ETS database is required for this 6-channel module?
To allocate physical addresses and configure parameters, engineers must use the SWI03 database, which is specifically designed for our 6-fold and 8-fold switch actuators. As of April 2026, the firmware and database are completely tested and fully compatible with ETS 6.4.1.
Q3: How does the manual forced switch assist onsite electrical teams?
The physical manual levers on the front panel provide a direct mechanical override to the internal relays. This allows electrical contractors to physically test lighting circuits, identify wiring faults, or turn on essential equipment during the early construction phases before the KNX bus is powered or programmed.
Q4: Can the built-in logic gates function without a central KNX server?
Yes. The actuator hardware includes integrated AND / OR logical operations. It can process group addresses directly from field sensors (like a thermostat and a window contact) to evaluate conditions locally. This decentralized architecture ensures the system continues to operate logically even if the central server goes offline.
Q5: What happens to the relay states during a facility power outage?
System stability is critical in B2B deployments. Through the ETS software, integrators can strictly define the output actions during KNX bus power loss, bus power recovery, and device blocking/non-blocking states. This ensures that facility infrastructure resets safely and predictably following grid disruptions.