Description
Strategic Relay Control for Large-Scale Building Automation
In the competitive landscape of B2B electrical contracting and smart city infrastructure, selecting the optimal hardware requires a delicate balance between functional depth and procurement efficiency. The SIXINSMART KNX 8-Fold 10A Switch Actuator (Model: SW0008.1001) is explicitly engineered to handle the opening and closing control of 8 distinct load circuits, with each output delivering a reliable rated current of 10A. This device is the quintessential workhorse for commercial lighting, fan control, and general-purpose switching in modern office towers, hotels, and institutional facilities.
Compliant with the stringent EN 60 715 installation standard, the SW0008.1001 mounts effortlessly onto standard 35mm DIN guide rails. Its intelligent design philosophy focuses on installation efficiency: the switch actuator is connected to the KNX system exclusively through the KNX bus terminal and operates entirely without the need for an additional power supply to control the load. This elegant, bus-powered topology minimizes cable clutter, mitigates thermal buildup in distribution panels, and accelerates the commissioning process for onsite engineering teams.
1. Intelligent Software & Logic Capabilities
Hardware is only half the equation in the KNX ecosystem. The allocation of physical addresses and the detailed setting of operational parameters require the use of the standardized ETS software. For the 8-fold actuator series, system integrators will rely on the powerful SWI03 database. This opens up a comprehensive suite of digital functions designed to handle complex environmental demands:
- Configurable Switch Delays: Engineers can precisely delay the setting of the on/off action. This prevents massive inrush currents from tripping main breakers when entire floors or building wings are powered on simultaneously.
- Enhanced Staircase Lighting: Includes an automated timer equipped with a vital warning function. Occupants will receive a visual cue (such as a brief light flicker) before the zone goes dark, a critical feature for stairwells, corridors, and underground parking garages.
- Granular Scene Management: Each of the 8 channels has 8 distinct scenes available for use. This allows individual lights to participate in various room presets—from “cleaning mode” to “presentation mode”—via a single group address command.
- Decentralized Logical Operations: The actuator natively processes AND & OR gate functions. It can evaluate multiple conditions (e.g., motion detected AND lux level below threshold) to actuate a load without relying on a centralized logic server.
- Comprehensive Status Feedback: Supports master general control (all-on/all-off) and provides reliable status value query replies, ensuring your Central BMS dashboard reflects the exact physical state of the building’s relays.
- Fail-Safe Behavior Configurations: Integrators can rigorously define the output actions during bus power on/off events, as well as define states for device blocking/non-blocking, ensuring the facility enters a secure state during power anomalies.
2. Complete Ordering Information (Series Matrix)
The SIXINSMART switch actuator series is highly scalable, available in 1, 2, 4, 6, 8, and 12 folds to meet the exact node density required by your project. Please refer to the official ordering table below to differentiate the SW0008.1001 from our higher-amperage variants.
| Order model | name | Current detection | Manual lever | LED |
|---|---|---|---|---|
| SW0001. 1611 | 1-fold 16A Switch actuator | Yes | Yes | No |
| SW0001.2010 | 1-fold 20A Switch actuator | Yes | Yes | No |
| SW0002. 1001
SW0004. 1001 |
2-fold 10A Switch actuator
4-fold 10A Switch actuator |
No
No |
No
No |
No
Yes |
| SW0004. 1611 | 4-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0004. 2010 | 4-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0006. 1001 | 6-fold 10A Switch actuator | No | No | Yes |
| SW0006. 1611 | 6-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0006. 2010 | 6-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0008. 1001 | 8-fold 10A Switch actuator | No | No | Yes |
| SW0008. 1611 | 8-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0008. 2010 | 8-fold 20A Switch actuator | Yes | Yes | Yes |
| SW0012. 1001 | 12-fold 10A Switch actuator | No | No | Yes |
| SW0012. 1611 | 12-fold 16A Switch actuator | Yes | Yes | Yes |
| SW0012. 2010 | 12-fold 20A Switch actuator | Yes | Yes | Yes |
3. Technical Parameters (SW00XX.1001 Series)
The engineering parameters below reflect the official specifications for the 10A switch actuator range, ensuring absolute precision for electrical layout planning.
| Parameter Category | SW00XX.1001 Specification | |
| KNX Input | KNX voltage | DC 21V~31V |
| KNX Current | <12mA | |
| KNX Power consumption | <360mW | |
| Wiring terminal | KNX cable | Require the use of KNX standards twisted pair cables that comply with |
| Torque | 0.8Nm | |
| Range of wiring diameter | $0.2-6mm^2 | |
| Output characteristic | Max Switching Current | 10A |
| Max switching power | 2500VA | |
| Mechanical Endurance | 10^6 | |
| Current detection | Not Supported on 10A Models | |
| Operation temperature | -25°C ~ + 55°C | |
| Installation | Installed on a 35 mm guide rail | |
| Appearance | Grey white, PVC material | |
| Authentication | KNX、CE | |
Strategic Procurement FAQ for System Integrators
1. Why does the SW0008.1001 exclude manual forced switches and current detection?
The 10A switch actuator series is value-engineered specifically for wholesale projects and standard commercial lighting where heavy inrush currents or predictive motor maintenance are not primary concerns. By excluding these specialized hardware features, the SW0008.1001 achieves a highly competitive price point for large-volume bidding while maintaining strict KNX standard reliability.
2. Which ETS database file is required for commissioning the KNX 8 Fold 10A Switch Actuator?
To assign physical addresses and configure the logic parameters, electrical contractors must utilize the SWI03 database. This specific database handles both the 6-fold and 8-fold actuators across all our switch series.
3. Is this actuator fully compliant with the latest ETS6 software?
Yes. We continuously ensure forward compatibility for modern smart building topologies. As of April 2026, the SW0008.1001 model is rigorously tested and confirmed to be fully compatible with the ETS6.4.1 environment, guaranteeing seamless programming for your engineering teams.
4. Does the unit require an external 24V DC DIN rail power supply to operate the 8 relays?
No. A key installation benefit of the SIXINSMART switch actuator series is its bus-powered design. The unit draws all necessary operating current (<12mA) directly from the KNX bus feed (DC 21V~31V). It does not require any additional auxiliary power supply, freeing up valuable space in your distribution boards.
5. If there are no manual switches, how can site engineers verify channel status?
While the manual force levers are omitted, the SW0008.1001 is fully equipped with independent LED status indicators for all 8 channels (as indicated in our ordering matrix). This provides immediate visual confirmation of the relay state during onsite inspection and troubleshooting.