SIXINSMART KNX 8 Fold 16A Switch Actuator SW0008.1611 | Professional Current Monitoring Relay with Manual Override & ETS6.4.1 Support

Engineering-Grade Power Control for B2B Integrators

  • High-Capacity 16A Output: Engineered for heavy-duty switching, each of the 8 channels supports a rated current of 16A, making it ideal for high-wattage lighting groups and industrial motor loads.
  • Real-Time Current Detection: Integrated sensing technology provides real-time current monitoring, overload alarms, and protective cut-offs, ensuring maximum electrical safety and facility uptime.
  • Rugged Manual Override Switch: Equipped with robust manual levers for each fold, allowing electrical contractors and site engineers to perform emergency forced switching and status inspection even without bus power.
  • Advanced Logical Operations: Built-in support for AND/OR logical gates enables complex local automation scenarios directly at the actuator level, reducing bus traffic and enhancing system reliability.
  • Flexible Scene & Lighting Modes: Features 8 programmable scenes per channel and a dedicated staircase lighting function with pre-warning dimming, providing sophisticated user experiences for commercial buildings.
  • Future-Proof ETS Compatibility: Fully authenticated by KNX and CE. As of April 2026, it is verified compatible with the latest ETS6.4.1 framework using the SWI03 database.
  • Professional Status Feedback: Supports status value query replies and general control functions, allowing central building management systems (BMS) to maintain accurate real-time data.
  • DIN Rail Efficiency: Compliant with EN 60 715 standards for 35mm guide rail installation. Powered directly by the KNX bus (<360mW), eliminating the need for auxiliary power supplies.
Download KNX Switch Actuator Technical Manual Download KNX Switch Actuator User Manual

Description

Industrial KNX 8-Fold 16A Actuator: The Foundation of Reliable Building Automation

In large-scale commercial and industrial automation projects, relay reliability and current sensing precision are the primary concerns for system integrators. The SIXINSMART SW0008.1611 is a high-performance 8-fold 16A switch actuator meticulously engineered to handle demanding electrical environments while providing the intelligence required for modern smart buildings.

This series complies with the EN 60 715 installation standard and is designed for a 35mm guide rail, ensuring seamless integration into international electrical distribution cabinets. The SW0008.1611 connects to the KNX system through the standard bus terminal, drawing minimal power (<12mA) and requiring no additional auxiliary power supply to control the load. This reduces wiring complexity and minimizes potential failure points in high-density installations.

Sophisticated Functionality for Complex Engineering

Unlike standard entry-level relays, the SW0008.1611 offers a comprehensive suite of software functions accessible via the ETS software (SWI03 database). Integrators can implement delay settings for on/off actions, ensuring sequential load activation to prevent peak current surges. The staircase lighting function includes vital warning features, enhancing safety in public spaces. Furthermore, each channel supports 8 scenes and logical operations (AND, OR), allowing the actuator to make local decisions, which is critical for fault-tolerant system design.

Enhanced Safety with Current Detection & Manual Control

Safety is paramount in B2B environments. The SW0008.1611 features real-time monitoring, overload alarms, and protective cut-off through its advanced current detection circuitry. This allows facility managers to identify abnormal energy consumption or potential failures before they lead to downtime. For site maintenance, the manual forced switch levers provide a tangible, mechanical interface to verify circuit integrity during commissioning or emergency situations, independent of the software state.

Ordering Information & Selection Guide

Order model name Current detection Manual lever LED
SW0001. 1611 1-fold 16A Switch actuator Yes Yes No
SW0001.2010 1-fold 20A Switch actuator Yes Yes No
SW0002. 1001 2-fold 10A Switch actuator No No No
SW0004. 1001 4-fold 10A Switch actuator No No Yes
SW0004. 1611 4-fold 16A Switch actuator Yes Yes Yes
SW0004. 2010 4-fold 20A Switch actuator Yes Yes Yes
SW0006. 1001 6-fold 10A Switch actuator No No Yes
SW0006. 1611 6-fold 16A Switch actuator Yes Yes Yes
SW0006. 2010 6-fold 20A Switch actuator Yes Yes Yes
SW0008. 1001 8-fold 10A Switch actuator No No Yes
SW0008. 1611 8-fold 16A Switch actuator Yes Yes Yes
SW0008. 2010 8-fold 20A Switch actuator Yes Yes Yes
SW0012. 1001 12-fold 10A Switch actuator No No Yes
SW0012. 1611 12-fold 16A Switch actuator Yes Yes Yes
SW0012. 2010 12-fold 20A Switch actuator Yes Yes Yes

3 Technical Parameters (SW0008.1611)

KNX Input KNX voltage DC 21V~31V
KNX Current <12mA
KNX Power consumption <360mW
Wiring terminal KNX cable Standard KNX twisted pair cables
Torque 0.8Nm
Range of wiring diameter 0.2-6mm²
Output characteristic Max Switching Current 16A
Max switching power 4000VA
Mechanical Endurance 10⁶
Current detection Yes
Operation temperature -25°C ~ +55°C
Installation Installed on a 35 mm guide rail
Appearance Grey white, PVC material
Authentication KNX, CE

B2B Integration & Procurement FAQ

Q1: How does the SW0008.1611 ensure reliability when handling 16A inductive loads?

Integrators often worry about relay contact welding with LED drivers. The SW0008.1611 utilizes high-quality industrial relays rated for 16A with a mechanical life of over 1,000,000 operations. Furthermore, the 16A capacity provides a robust overhead for inrush currents common in electronic ballasts, making it significantly more reliable than standard 10A modules.

Q2: What are the specific integration benefits of real-time current detection in commercial projects?

For B2B projects, current detection isn’t just about measurement; it’s about facility maintenance. It allows the KNX system to report energy consumption per channel and trigger alarms if a load (like a motor or heater) deviates from its normal operation range. This predictive maintenance capability is a major selling point for smart building consultants.

Q3: Is the SW0008.1611 compatible with the latest ETS6 software updates?

Yes. As of April 2026, SIXINSMART switch actuators are fully certified for compatibility with ETS6.4.1. Integrators should use the SWI03 database for the 8-fold series to unlock advanced logic and current monitoring parameters. We ensure that our databases are updated regularly to support the latest KNX engineering standards.

Q4: Why is a manual forced switch lever important for onsite commissioning?

During the construction phase, the KNX bus may not be fully powered or programmed. The mechanical manual override allows electrical contractors to physically toggle the circuit to test load wiring. It also serves as a critical fail-safe during emergency maintenance, allowing manual control independent of the software logic.

Q5: Can the SW0008.1611 operate without an external power supply?

Yes, the actuator is fully bus-powered. It connects to the KNX/EIB bus via a standard terminal and consumes less than 12mA (360mW). This “bus-only” power architecture simplifies distribution board design and reduces the thermal load within the cabinet, which is essential for dense 28-fold or multi-actuator setups.