Description
The Next-Generation Backbone for DALI-2 Integration
The SIXINSMART G-DDW series is engineered as a high-performance bridge between KNX TP and DALI-2 (IEC 62386). Unlike standard gateways, it features a Split Architecture (DALI layer and KNX layer separation), ensuring that high-speed DALI data processing never causes jitter on the KNX bus. Supporting up to 128 LED drivers (2×64), this gateway is the definitive solution for large-scale lighting deployments that demand 0.1% (1/1000) precision dimming, DT8 Color Temperature management, and ultra-stable long-term operation.
Revolutionary TCP Debugging: Parallel Workflow for Integrators
Site commissioning is often a bottleneck. Our unique TCP Interface Debugging logic changes the game. The G-DDW series supports two engineers simultaneously debugging a single gateway via LAN. While one technician addresses drivers on Channel A, another can configure scenes for Channel B. This concurrent multi-user access, combined with Batch Provisioning and online editing, slashes commissioning labor costs and significantly improves deployment speed for overseas wholesalers and engineering integrators.
Intelligent Traffic Management: Message Rate Limiting
To prevent “broadcast storms” and KNX bus saturation, we have implemented a proprietary Telegram Rate Limiting (Message Restriction) strategy. The gateway intelligently manages status feedback from 128 devices, ensuring that critical control commands always receive priority. This ensures a responsive, lag-free user experience even in high-density environments where hundreds of status updates are being reported autonomously.
Complete Operation, Display & LED Logic (Direct from Specification)
The G-DDW series provides comprehensive visual feedback and tactile site-testing capabilities. These hardware-level controls are essential for verification during the construction phase before the KNX bus is fully commissioned.
| Component | Operational Logic / Status Definition |
| Programming Button | Used for Setting Physical Addresses via ETS. |
| Manual Button / LED Indicator | Provides local Manual Control and real-time status Indication. |
| LED (Status) Indicator | • Solid Red: Entered ETS Download Mode • Flashing Red: Bus Fault Detected • Flashing Amber: DALI Bus Activity Detected (Traffic Active) • Solid Amber: Broadcast Switch State – ON • Solid Green: Broadcast Switch State – OFF and DALI Bus Normal |
| Test/Set Buttons (Action Triggers upon Release) | • Press (< 5S): Instant Broadcast ON/OFF (Site Testing) • Press and hold (> 5S): Commissioning Unaddressed Devices (Auto-addressing) • Press and hold (> 10S): Full System Readdressing (Hard Reset Address Mapping) |
Full Technical Parameters (Pixel-Level Reproduction)
| Category | Parameter Name | G-DDW1.1 | G-DDW2.1 |
|---|---|---|---|
| Power Supply | Input voltage | 100-240V~ AC, 50/60Hz | |
| Input current | 0.1A | 0.15A | |
| KNX bus voltage | 21-30V DC | ||
| KNX bus current | <5mA | <6mA | |
| Bus power consumption | <150mW | <180mW | |
| DALI bus voltage | 16V±2V DC | ||
| DALI current consumption | Max. 200mA | Max. 2x 160mA | |
| Connect | Screw-type terminal blocks | 0.5-4.0mm² solid line, 0.5-2.5mm² multi-strand line | |
| KNX bus terminals | 0.8mm, solid line | ||
| Environment | Working temperature | -5~+45℃ | |
| Storage temperature | -20~+60℃ | ||
| Working humidity | 10~95% RH, no condensation | ||
| Dimension | Dimension | 72*90*64.5mm (W*H*D) | |
| Width unit | 4SU | ||
| Track installation | 35mm ding guide rail | ||
Remark: 1. Unless otherwise specified, all specifications are measured at an input of 230VAC, rated load, and an ambient temperature of 25℃. 2. Provide a test report from a certification body.
Engineering Commissioning & Fault Diagnostics
Q: How do we interpret the LED status during on-site commissioning?
A: The G-DDW series uses a multi-color LED logic: Solid Red means ETS Download mode; Flashing Red indicates a bus hardware fault; Flashing Amber confirms active DALI traffic; Solid Amber means Broadcast is ON; and Solid Green indicates normal bus status with Broadcast OFF.
Q: How do we trigger re-addressing or site testing without a PC?
A: Use the Test/Set buttons on the faceplate. A short press (<5S) toggles Broadcast ON/OFF for light testing. Holding for >5S triggers auto-commissioning for unaddressed drivers. Holding for >10S forces a full system re-addressing, which is critical when drivers are replaced or the bus is re-wired.
Q: What is the “Message Restriction” feature used for?
A: In systems with 128 nodes, status feedback can easily flood the KNX bus. Our gateway limits the rate of non-critical telegrams, ensuring that even during mass dimming operations, the KNX bus occupancy remains below critical thresholds to prevent system lag.