SIXINSMART Industrial KNX to DALI 2 Gateway | 1/2-Channel 128-Device Controller | 0.1% Precision Dimming & Multi-User TCP Debugging | Split Architecture with Message Rate Limiting

ENGINEERING KILLER FEATURES

  • ● Multi-User TCP Debugging:
    Industry-exclusive TCP interface allows two engineers to debug a single gateway simultaneously. Supports parallel configuration of two DALI channels, drastically reducing on-site labor time for large projects.
  • ● Ultra-Precision 0.1% Dimming:
    Achieve cinematic 1/1000 precision control. Perfect for luxury hotels and architectural landmarks requiring seamless, flicker-free transitions and perfect linear dimming curves.
  • ● Split-Layer Architecture:
    Total separation of DALI management and KNX communication layers. This decoupled design ensures high-speed DALI polling never interferes with KNX bus stability, even with 128 devices active.
  • ● Intelligent Message Restriction:
    On-board Telegram Rate Limiting algorithm prevents KNX bus congestion. Filters redundant status feedback and ensures critical lighting commands are executed with absolute priority.
  • ● DALI-2 & DT8 Certified:
    Full support for On/Off, Brightness, and Color Temperature (Tunable White). Supports 16 groups and 16 scenes per channel, guaranteeing interoperability with all global DALI-2 drivers.
  • ● Advanced Hardware Diagnostics:
    Autonomous fault reporting for lamp failure and driver disconnect. Integrated LED status codes (Amber/Green/Red) and tactile Test/Set buttons allow for full site verification without software.
  • ● Professional Industrial Chassis:
    4SU (72mm) DIN-rail build with 3.75KV AC isolation. Integrated DALI power supply (200mA/160mA) and 100-240V AC wide-range input for global electrical stability.

 

Download SIXINSMART KNX DALI 2 Gateway Specification

 

Download SIXINSMART KNX DALI 2 Operation Manual

Description

The Next-Generation Backbone for DALI-2 Integration

The SIXINSMART G-DDW series is engineered as a high-performance bridge between KNX TP and DALI-2 (IEC 62386). Unlike standard gateways, it features a Split Architecture (DALI layer and KNX layer separation), ensuring that high-speed DALI data processing never causes jitter on the KNX bus. Supporting up to 128 LED drivers (2×64), this gateway is the definitive solution for large-scale lighting deployments that demand 0.1% (1/1000) precision dimming, DT8 Color Temperature management, and ultra-stable long-term operation.

Revolutionary TCP Debugging: Parallel Workflow for Integrators

Site commissioning is often a bottleneck. Our unique TCP Interface Debugging logic changes the game. The G-DDW series supports two engineers simultaneously debugging a single gateway via LAN. While one technician addresses drivers on Channel A, another can configure scenes for Channel B. This concurrent multi-user access, combined with Batch Provisioning and online editing, slashes commissioning labor costs and significantly improves deployment speed for overseas wholesalers and engineering integrators.

Intelligent Traffic Management: Message Rate Limiting

To prevent “broadcast storms” and KNX bus saturation, we have implemented a proprietary Telegram Rate Limiting (Message Restriction) strategy. The gateway intelligently manages status feedback from 128 devices, ensuring that critical control commands always receive priority. This ensures a responsive, lag-free user experience even in high-density environments where hundreds of status updates are being reported autonomously.

Complete Operation, Display & LED Logic (Direct from Specification)

The G-DDW series provides comprehensive visual feedback and tactile site-testing capabilities. These hardware-level controls are essential for verification during the construction phase before the KNX bus is fully commissioned.

Component Operational Logic / Status Definition
Programming Button Used for Setting Physical Addresses via ETS.
Manual Button / LED Indicator Provides local Manual Control and real-time status Indication.
LED (Status) Indicator • Solid Red: Entered ETS Download Mode
• Flashing Red: Bus Fault Detected
• Flashing Amber: DALI Bus Activity Detected (Traffic Active)
• Solid Amber: Broadcast Switch State – ON
• Solid Green: Broadcast Switch State – OFF and DALI Bus Normal
Test/Set Buttons (Action Triggers upon Release) • Press (< 5S): Instant Broadcast ON/OFF (Site Testing)
• Press and hold (> 5S): Commissioning Unaddressed Devices (Auto-addressing)
• Press and hold (> 10S): Full System Readdressing (Hard Reset Address Mapping)

Full Technical Parameters (Pixel-Level Reproduction)

Category Parameter Name G-DDW1.1 G-DDW2.1
Power Supply Input voltage 100-240V~ AC, 50/60Hz
Input current 0.1A 0.15A
KNX bus voltage 21-30V DC
KNX bus current <5mA <6mA
Bus power consumption <150mW <180mW
DALI bus voltage 16V±2V DC
DALI current consumption Max. 200mA Max. 2x 160mA
Connect Screw-type terminal blocks 0.5-4.0mm² solid line, 0.5-2.5mm² multi-strand line
KNX bus terminals 0.8mm, solid line
Environment Working temperature -5~+45℃
Storage temperature -20~+60℃
Working humidity 10~95% RH, no condensation
Dimension Dimension 72*90*64.5mm (W*H*D)
Width unit 4SU
Track installation 35mm ding guide rail

Remark: 1. Unless otherwise specified, all specifications are measured at an input of 230VAC, rated load, and an ambient temperature of 25℃. 2. Provide a test report from a certification body.

Engineering Commissioning & Fault Diagnostics

Q: How do we interpret the LED status during on-site commissioning?

A: The G-DDW series uses a multi-color LED logic: Solid Red means ETS Download mode; Flashing Red indicates a bus hardware fault; Flashing Amber confirms active DALI traffic; Solid Amber means Broadcast is ON; and Solid Green indicates normal bus status with Broadcast OFF.

Q: How do we trigger re-addressing or site testing without a PC?

A: Use the Test/Set buttons on the faceplate. A short press (<5S) toggles Broadcast ON/OFF for light testing. Holding for >5S triggers auto-commissioning for unaddressed drivers. Holding for >10S forces a full system re-addressing, which is critical when drivers are replaced or the bus is re-wired.

Q: What is the “Message Restriction” feature used for?

A: In systems with 128 nodes, status feedback can easily flood the KNX bus. Our gateway limits the rate of non-critical telegrams, ensuring that even during mass dimming operations, the KNX bus occupancy remains below critical thresholds to prevent system lag.