Description
Professional KNX Microwave Motion & Illuminance Sensor: The Ultimate Solution for Smart Building Automation
In the demanding sector of commercial building automation, precision and reliability are non-negotiable. The SIXINSMART F-CMMS.1 KNX Microwave Motion Sensor represents the pinnacle of presence detection technology. Utilizing advanced 5.8GHz microwave detection, this sensor transcends the limitations of traditional PIR sensors by offering superior sensitivity to minor movements, even through thin partitions or glass. Engineered for seamless integration into KNX bus systems, it serves as the intelligent eyes for modern offices, luxury hotels, and high-end residential projects.
Sophisticated Occupancy Detection & Lighting Control
The F-CMMS.1 is not merely a motion detector; it is a comprehensive environmental management module. By combining high-frequency motion sensing with an integrated illuminance sensor, it enables true Constant Lumen Output (CLO). This ensures that workspace lighting remains at a consistent, pre-configured lux level by dynamically adjusting output based on natural daylight availability. For project integrators, this translates to maximum energy efficiency and enhanced occupant comfort, meeting the stringent green building standards required in the global market.
Versatile Operating Modes for Complex Engineering Requirements
Understanding that every architectural space has unique logic requirements, this sensor supports Full-automatic and Semi-automatic modes. It can function in a Master/Slave configuration, allowing multiple sensors to cover expansive areas such as open-plan offices or long corridors without logic conflicts. The built-in Logical Functions and Scene Group Functions allow installers to program complex “if-then” scenarios—such as triggering different lighting scenes during daytime versus nighttime—directly within the device, reducing the processing load on the central KNX backbone.
Technical Parameters & Specifications
Strictly compliant with the KNX standard, the following parameters define the operational excellence of the F-CMMS.1 module:
| Category | Parameter Name | F-CMMS.1 Specifications |
|---|---|---|
| Basic Parameters | Communication Method | KNX |
| KNX Bus Voltage | 21-30V DC | |
| KNX Bus Current | < 12mA | |
| KNX Power Consumption | < 360mW | |
| Auxiliary Power | Auxiliary Voltage | 20-30V DC |
| Auxiliary Current | < 30mA | |
| Auxiliary Power Consumption | < 900mW | |
| Environmental Conditions | Operating Temperature | -5°C ~ +45°C |
| Storage Temperature | -25°C ~ +55°C | |
| Operating Humidity | < 93% RH (No condensation) | |
| Detection Performance | Microwave Frequency | 5.8GHz |
| Motion Detection Radius | Max 6m (Installation height < 4m) | |
| Physical Installation | Dimensions | Φ67 x 40mm (Recessed Φ52mm) |
| Mounting Method | Ceiling Embedded / Snap-on clips |
Engineering Excellence for Global Integrators
The compact design (Φ67mm) and 55mm depth requirements ensure that the F-CMMS.1 can be installed in almost any ceiling type with minimal aesthetic impact. With 4 adjustable sensing ranges, engineers can fine-tune the detection zone to prevent false triggers from adjacent hallways or mechanical vibrations. Whether you are designing a KNX-based lighting system for a commercial high-rise or a smart hotel suite, this microwave sensor delivers the accuracy, flexibility, and longevity required for professional-grade automation.
Expert Technical FAQ: KNX Microwave Presence Solutions
Q1: Why choose 5.8GHz microwave technology over standard PIR sensors for commercial KNX projects?
A: Microwave sensors, like the F-CMMS.1, use active Doppler radar technology. Unlike PIR sensors which require a line-of-sight and detect heat signatures, our 5.8GHz microwave sensor can detect minute movements (like typing or breathing) even through thin partitions and glass. This makes it ideal for modern office layouts with glass partitions where PIR sensors often fail to maintain presence detection.
Q2: How does the Constant Lumen Output (CLO) function benefit large-scale building energy management?
A: The CLO function utilizes the integrated illuminance sensor to measure ambient light levels. It then communicates with KNX dimming actuators to provide only the necessary amount of artificial light to reach a target lux level. This “daylight harvesting” significantly reduces energy consumption and extends the lifespan of lighting fixtures, a key requirement for B2B engineering projects focused on sustainability.
Q3: Can this sensor operate as a standalone logic controller within a KNX network?
A: Yes. The F-CMMS.1 features integrated logic and scene group functions. It can process internal data (motion + illuminance) and external group objects to trigger complex scenes without requiring an external logic module. It also supports Master/Slave modes to synchronize multiple sensors in expansive installation areas.
Q4: What is the maximum recommended installation height and detection coverage?
A: For optimal performance, the sensor should be installed at a height of less than 4 meters. At this height, it provides a maximum motion detection radius of 6 meters. The sensor also offers 4 different sensing range adjustments via ETS software to customize coverage for specific room sizes.
Q5: What are the auxiliary power requirements for the F-CMMS.1?
A: This sensor requires an auxiliary power supply of 20-30V DC in addition to the KNX bus connection. The auxiliary power ensures the microwave detection module operates at peak sensitivity without drawing excessive current from the main KNX TP bus, maintaining overall system stability.