KNX RCU Room Control Unit RM0448.1611 – All-in-One Smart Hotel & Office Actuator with Built-in IP Router, RS485 Gateway, and 15-Channel Dynamic Relays

Ultimate Centralized Room Automation (RCU)

  • ■ Unprecedented Integration Density: The RM0448.1611 Room Control Unit replaces up to eight individual KNX modules. By integrating a 4-fold 16A switch, 2-fold shutter actuator, fan coil controller, 6-fold 0-10V LED dimming, and a 12-fold universal interface into a single 126mm wide footprint, integrators drastically reduce DIN rail space, wiring complexity, and hardware costs per room.
  • ■ 15-Channel Dynamic Relay Matrix: The internal 15-channel relay architecture is dynamically configurable via software. Engineers can allocate the mechanical relays flexibly to serve as high-current lighting switches, AC motor shutter controls, or multi-speed fan coil outputs, adapting seamlessly to changing architectural requirements without swapping physical hardware.
  • ■ Built-In Backbone Infrastructure (IP & RS485): Uniquely features a fully functional 1-fold IP Router for high-speed Ethernet backbone line coupling and central BMS communication. Concurrently, the 2-fold RS485 gateway acts as a Modbus RTU host, bridging third-party HVAC, smart meters, and legacy RS485 devices directly into the KNX ecosystem.
  • ■ 2026 Future-Proof Software Certification: Extensively audited and certified for the latest KNX engineering environments. As of our global statistical update in April 2026, this RCU is 100% compatible with ETS6.4.1, supporting advanced secure commissioning, modular parameterization, and seamless firmware flashing.
  • ■ Universal I/O Flexibility: The 12-fold universal interface supports both passive and active inputs with complete electrical isolation from the KNX bus. This allows for the integration of low-cost mechanical dry contacts, keycard switches, and 12VDC output load controls from a single localized node.
Download SIXINSMART KNX RCU User Manual Download SIXINSMART KNX RCU Technical Manual

Description

Redefining Topology: The KNX Room Control Unit (RM0448.1611)

In high-density commercial projects such as 5-star hospitality suites, luxury residential apartments, and premium office spaces, decentralized control introduces unacceptable wiring overhead and cabinet sprawl. The SIXIN KNX RCU RM0448.1611 is a masterclass in centralized node engineering. It consolidates the entirety of a room’s automation requirements—lighting, climate, shading, multimedia, and backbone networking—into one highly robust, CE and KNX certified device.

By leveraging a dynamic configuration architecture, this RCU provides unprecedented asset flexibility. Integrators no longer need to calculate the exact ratio of switch actuators to shutter actuators prior to deployment. The internal relays and 0-10V outputs can be software-defined via the ETS configuration tool to match the precise as-built requirements of the space.

Comprehensive Sub-System Capabilities

1. Switch & Shutter Actuation

The core power management is handled by independent electrical communication load outputs. The 4-fold Switch Actuator manages up to 16A/220VAC per contact, featuring critical current measurement functions, logical operations (AND, OR, XOR, GATE), and whole staircase lighting profiles. When shading is required, the 2-fold Shutter Actuator delivers precise AC motor control (10A/220VAC) with adjustable open/close latency and scene integration. If shutters are omitted from the room design, these channels can be repurposed as standard 8-fold (A…H) switch actuators.

2. Advanced Climate Control (Fan Coil)

The dedicated Fan Coil Actuator guarantees thermal comfort. It supports single-phase fans up to three speeds alongside comprehensive control of heating and cooling thermal valves. The logic engine natively supports 2-pipe, 3-pipe, and 4-pipe HVAC infrastructures, complete with automatic and manual modes, ensuring rapid room temperature stabilization according to BMS setpoints.

3. 0~10V LED Dimming (6-Fold)

Architectural lighting demands smooth transitions. The built-in 6-fold 0~10V Dimming Actuator provides a 0~10V/5mA drive output perfectly isolated from the KNX bus. This delivers exceptional linearity for soft, uniform lighting. Furthermore, engineers can configure the 6-fold outputs into 2 independent sets of RGB 3-base tone lighting for dynamic wall washing and LED strip control.

4. 12-Fold Universal Interface

Serving as the sensory nervous system of the room, the 12-fold Universal Interface accommodates both input and output parameters. Inputs process passive/active signals with full electrical isolation, supporting edge control, one-key dimming, shutter step/move commands, and edge counters. Outputs can deliver a 12VDC level to drive auxiliary low-voltage loads or LED indicators.

5. Backbone Connectivity: RS485 & IP Router

The RM0448.1611 transcends standard actuation by acting as a network bridge. The 2-fold RS485 Gateway functions as a Modbus Host, seamlessly bringing Modbus RTU field devices into the KNX visualization. Simultaneously, the 1-fold IP Router enables Ethernet line coupling, 10/100Mb auto-negotiation, group message filtering, and direct centralized host control over the entire room infrastructure.

Technical Parameter

Category Parameter Specification
Power Supply Power Input 10-30VDC
KNX-BUS power DC 21V-31V
Static bus current < 6mA
EIB/KNX bus It is required to use the KNX standard double stranded cable (0.8mm in diameter) and the KNX bus terminal
Main Functions Switch Actuator 4-fold, 16A, with current measurement
Shutter Actuator 2fold-, motor control
Fan Coil Actuator Control of 3-speed fans/ventilator convectors, Control thermal heating and cooling valves
0~10V LED Dimming Actuator 6-fold,0-10V output
Universal Interface 12-fold input/output
Audio Play This model is not supported; RM0449.1611 is supported.
RS485 Gateway 2-fold
IP Router 1-fold
Operation and display interface Programming button Button assigns physical address
Programming LED Light on means device is in programming status
Protection type IP20 EN60529
Protection class II EN61140
Temperature range Operation -5°C…+45°C
Storage -25°C….+55°C
Transport -30°C…+70°C
Environmental Requirement Max air humidity 93%, except moisture condensation
Specifications Volume 126mm*90mm*63 mm
Weight Around 580g
Installation Standard 35mm U-shape rail of the distribution box
Appearance Grey white、P
Certification KNX EN50090-1 EN50090-2

Global Systems Integrator FAQ: KNX RCU RM0448.1611

Q1: How exactly does the dynamic relay allocation optimize commercial project deployments?

A: In traditional KNX topologies, integrators must purchase dedicated modules for lighting (Switches) and dedicated modules for blinds (Shutters). The KNX RCU Contains Switch Actuator RM0448.1611 utilizes a 15-channel dynamic relay matrix. Through the ETS interface, you can designate unused 2-fold shutter channels to operate as standard 8-fold switch actuators (A…H). This dynamic reconfiguration ensures 100% hardware utilization, preventing stranded assets in the distribution box and lowering the overall cost-per-node for hotel and office automation.

Q2: What is the primary operational advantage of the built-in 1-fold IP Router?

A: Integrating an IP Router directly into the Room Control Unit dramatically flattens the network architecture. It provides high-speed Ethernet backbone connectivity (10/100Mb auto-negotiation) directly to the room. It performs intra-domain message exchange, line coupling, and essential group message filtering/blocking. This allows the central Building Management System (BMS) to address, download to, and monitor thousands of individual room modules simultaneously without bogging down a traditional twisted-pair KNX backbone.

Q3: Can the 2-fold RS485 Gateway interface with proprietary third-party HVAC equipment?

A: Yes. The integrated RS485 Gateway operates as a Modbus Host utilizing the Modbus RTU (Remote Terminal Unit) protocol. This allows the KNX RCU to directly read and write to third-party intelligent thermostats, VRV/VRF air conditioning gateways, or smart energy meters deployed within the room. By translating Modbus registers into KNX group addresses internally, it eliminates the need for expensive, standalone protocol converters.

Q4: Is the database and firmware of the RM0448.1611 validated for the latest ETS versions?

A: Absolutely. Future-proofing your engineering deployment is our top priority. Based on our comprehensive certification audits concluding in April 2026, the product database is completely certified and 100% compatible with ETS6.4.1. It fully supports KNX Secure parameters, logical gate programming (AND/OR/XOR), and advanced scene deployments within the modern ETS6 workflow.

Q5: How does the 12-fold Universal Interface handle active vs. passive inputs?

A: The 12-fold Universal Interface is remarkably versatile. For passive inputs (like standard mechanical light switches or magnetic door contacts), it relies on the internal sensing voltage, maintaining strict electrical isolation from the KNX bus. For output scenarios, the channels can provide a 12VDC level to directly drive indicator LEDs on bespoke wall plates or control small low-voltage auxiliary relays. Both modes support deep object blocking and logical operation configurations directly within the device.