Wholesale KNX 24GHz Biological Presence Detector SS3006.0101 | True Presence Respiratory Sensor & Constant Light Controller

Core Engineering Advantages

  • ✔ 24GHz Biological Live Detection
    Transcends standard PIR technology. Utilizes advanced millimeter-wave radar to capture micro-movements and respiratory signals, ensuring lights never turn off on stationary occupants. Delivers a highly accurate presence diameter of 2m to 6m.
  • ✔ Verified ETS6.4.1 System Integration
    Designed for flawless, long-term infrastructure deployments. Hardware is CE and KNX certified, with the application database fully verified for stable programming within the latest ETS6.4.1 environment (Validated as of April 2026).
  • ✔ 10-Tier Radar Sensitivity Tuning
    Empowers field technicians to sculpt the detection geometry. Features 10 adjustable sensitivity levels in ETS to prevent false triggers from adjacent zones, HVAC vibrations, or glass-partitioned hallways.
  • ✔ Highly Versatile Output Topologies
    Adapts to complex architectural scenes. Generates standard 1-bit switching data, granular 1-byte dimming percentages, or multi-device scene value outputs. Includes dedicated standby modes for dimmable safety lighting.
  • ✔ Master-Slave Network Optimization
    Scales perfectly across open-plan offices. Links multiple slave sensory nodes to a single logic Master, preventing conflicting actuator commands and drastically reducing KNX bus data congestion.
  • ✔ Dynamic Day/Night Automations
    Offers completely independent parameter configurations for day and night operating shifts. Instantly switchable via external network telegrams to align with sophisticated corporate security and energy protocols.
Download SIXINSMART KNX Biopresence Detector (24GHz) User Manual Download SIXINSMART KNX Biopresence Detector (24GHz) Technical Manual

Description

Next-Generation Commercial Automation: KNX Ceiling Mount 24GHz Biological Presence Detector

Redefining spatial occupancy through millimeter-wave live detection technology. Engineered exclusively for global system integrators and commercial electrical wholesalers.

The evolution of smart commercial buildings demands a paradigm shift from simple motion tracking to absolute, infallible human presence awareness. The KNX Ceiling Mount Biological Presence Detector (Model: SS3006.0101) represents the pinnacle of localized environmental bus sensing. Moving far beyond the limitations of traditional Passive Infrared (PIR) and standard microwave sensors, this device harnesses the power of 24GHz millimeter-wave (mmWave) radar technology. It is designed to capture the most minute biological signatures—including the subtle expansion of a human chest during breathing—achieving true “Live Detection.” For electrical engineering contractors outfitting executive boardrooms, specialized medical facilities, quiet study lounges, and modern open-plan offices, this sensor guarantees that occupants will never be left in the dark during static, focused tasks.

As a native component of the KNX ecosystem, the SS3006.0101 operates directly on the twisted-pair bus without necessitating proprietary gateways. It proudly carries rigorous CE and KNX quality certifications, securing its position in premium international procurement tenders. To ensure seamless, future-proof commissioning for your field technicians, the hardware architecture and product database are extensively verified for complete compatibility with the ETS6.4.1 programming environment (Statistical system verification data officially complete and accurate up to April 2026). This guarantees a risk-free integration matrix into any sophisticated Building Management System (BMS).

True Presence: The 24GHz Biological Detection Difference

Standard motion detectors inherently suffer from “dropout” issues when occupants remain seated or motionless for extended periods. The SS3006.0101 solves this chronic industry pain point. By emitting a continuous 24GHz radar wave and analyzing the Doppler shifts with unparalleled resolution, the sensor classifies occupancy into three distinct strata:

  • Macro-Movement Detection: Captures walking and large bodily transitions as personnel enter or navigate the space.
  • Micro-Movement Detection: Identifies fine motor skills, such as typing on a keyboard, using a computer mouse, or shifting slightly in a desk chair.
  • Respiratory Signal Detection: The ultimate fail-safe. Even if an occupant is meditating, sleeping in an on-call room, or reading perfectly still, the sensor detects the rhythmic biological signal of respiration, ensuring the lighting and climate control remain active.

Optimized for flush-mount ceiling installations between 2m and 3m in height, this device creates a highly focused sensory umbrella. It provides a reliable movement induction diameter of 4m to 8m, and a hyper-sensitive true biological presence diameter of 2m to 6m, perfectly covering standard workstation clusters or executive desks.

Integrated Constant Illuminance & Daylight Harvesting

Beyond biological tracking, the SS3006.0101 is a comprehensive environmental manager. It features an onboard, high-precision constant illuminance sensor with a massive operational measuring range spanning from 1 lux to 60k lux. This allows the device to execute advanced daylight harvesting protocols automatically.

By continuously sampling the ingress of natural sunlight into the office or corridor, the detector autonomously throttles connected KNX dimming actuators. It calculates the exact artificial capacity required to maintain the architect’s specified target brightness (e.g., a constant 500 lux on a work desk). This closed-loop regulation minimizes the load working cycle, achieving substantial reductions in electrical OPEX while simultaneously preventing user eye strain caused by over-illumination. System integrators can independently calibrate these lux values internally or sync them with external KNX weather stations, and set the sensor to cyclically broadcast real-time brightness data onto the bus for central dashboard visualization.

Advanced KNX Logic Control & Master-Slave Network Architecture

The internal ETS parameterization of the SS3006.0101 is engineered to accommodate the most demanding corporate lighting specifications:

  • Multi-Format Output Topologies: Upon confirming biological presence, the sensor can trigger 1-bit switching values, transmit precise 1-byte dimming percentages, or recall complex 1-byte scene mappings (e.g., dropping blinds, adjusting HVAC, and dimming lights simultaneously for a “Presentation” scene).
  • Independent Day/Night Profiles: Operational logic can be radically altered based on the time of day. Through an external KNX telegram switch, the detector can utilize aggressive daylight harvesting during business hours, and instantly swap to a low-output, 15% dimming “Standby Mode” for night-shift security patrols.
  • Dynamic Operating Modes: Integrators can deploy the unit in Fully Automatic mode (trigger on entry, off on exit), Manual mode, or Semi-Automatic mode. In Semi-Automatic, a user must manually press a wall switch to illuminate the room, but the biological sensor takes over to automatically extinguish the lights once the space is completely vacated and the idle cycle expires—ideal for conference rooms.
  • Master-Slave Grid Efficiency: To cover massive architectural footprints without choking the KNX bus bandwidth, multiple SS3006.0101 units can be networked. Slave detectors solely monitor for biological signatures and pass lightweight flags to a single Master node. The Master aggregates this data, calculates the constant light requirements, and executes the final command to the actuators.
  • 10-Level Sensitivity Tuning: Engineers can fine-tune the 24GHz radar’s responsiveness across 10 distinct levels, allowing them to shrink or expand the detection bubble to prevent false triggers from adjacent hallways or mechanical vibrations.

Technical Parameters

Parameter Specification
KNX bus power supply DC 21V~31V
Supply current < 15mA
Power consumption <450mW
Programming keys Press the mask
Programming indicator light LED
Maximum radius for micro motion detection 4-5 meters, height 3 meters
Maximum radius for presence detection 3-4 meters, height 3 meters
Sensitivity adjustable level Level 10
Sensitivity level corresponds to distance, And accurate distance is only supported by SS3007 Level 1: Within 0.5 meters (inclusive); Levels 2 to 10 correspond to levels 1 to 9 meters (inclusive), with an additional 1 meter for each level added;
Mounting height 2.5~3.0m, SS3007 up to 8m
installation Suction top mount
The ambient light measuring range 1 lux – 60k lux
Temperature measurement range -20℃~55℃, ±1.5°C
Working temperature -5°C~+45°C
Long-term storage temperature -25°C~+55 °C
Temperature in transit -30°C~+70°C

Global Procurement & Engineering FAQ

Q1: What exactly defines “Live Detection” in the KNX 24GHz Biological Presence Detector compared to standard microwave sensors?

Answer: Standard 5.8GHz microwave sensors can detect walking and large arm movements but struggle with stationary occupants. The SS3006.0101 utilizes a high-resolution 24GHz millimeter-wave (mmWave) radar. This specific high-frequency bandwidth provides extreme granular resolution, allowing the firmware to detect the micro-expansion of a human chest cavity during normal respiration. This means that even if a person is sleeping, reading without moving, or standing perfectly still, the sensor registers a “true presence” signal. It completely eradicates the issue of office lights turning off on employees who are typing quietly at their desks.

Q2: Is the SS3006.0101 officially verified for deployment within the latest ETS software environments?

Answer: Absolute software stability is guaranteed. The hardware is fully CE and KNX certified. Furthermore, the product application database (.knxprod) has been rigorously tested and is fully compatible with the ETS6.4.1 programming interface (with statistical verification data remaining current through April 2026). Electrical contractors can import the device, map complex logical group addresses, and execute field commissioning without encountering legacy software architectural conflicts.

Q3: Why would a system integrator choose the Semi-Automatic working mode over the Fully Automatic mode?

Answer: The Semi-Automatic mode is highly requested for specific corporate scenarios like AV presentation rooms or lecture halls. In Fully Automatic mode, the lights will turn on the second someone enters. In Semi-Automatic mode, the occupant must consciously press a KNX wall switch to turn the lights on, giving them the choice to leave the lights off if they are setting up a projector. However, the true presence detector still takes over the turn-off sequence. Once the room is empty and the idle cycle timer zeroes out, the detector automatically issues the OFF telegram, preventing the severe energy waste of human forgetfulness.

Q4: How does the master-slave network function handle large-scale architectural open spaces?

Answer: A single detector is optimally installed at 2.5m to 3m to cover an 8m diameter. For a sprawling 50-meter open-plan office, deploying multiple independent sensors would create chaotic bus traffic and conflicting dimming commands. The master-slave configuration solves this beautifully. You designate one unit as the logic Master, and install multiple Slave units across the floor plan. The slaves perform localized biological sensing and push tiny 1-bit presence flags to the Master. The Master aggregates these signals, evaluates the room’s total lux level, and pushes a single, unified 1-byte dimming or switching command to the KNX actuators. This ensures a unified lighting experience and protects critical bus bandwidth.

Q5: Can the biological sensitivity be adjusted if the radar is picking up movement from an adjacent room?

Answer: Yes. Because 24GHz mmWave radar has high penetration capabilities, it might occasionally detect movement through thin drywall or glass partitions. To mitigate this during commissioning, the ETS application provides 10 distinct motion detection sensitivity levels. Field engineers can dial down the sensitivity (e.g., from Level 10 down to Level 5) to precisely shrink the detection radius, ensuring the sensor strictly monitors the target room without generating false triggers from the hallway.