Description
Enterprise-Grade KNX Biological Presence & Constant Illuminance Sensor
The ultimate 24GHz mmWave radar solution for true live occupancy detection and automated daylight harvesting. Engineered for system integrators, commercial real estate developers, and global electrical wholesalers.
The threshold for what defines a “smart” building has fundamentally shifted. Relying on legacy motion detectors that leave occupants in the dark during periods of focused, stationary work is no longer acceptable in premium commercial architecture. The SIXIN KNX Ceiling Mount Biological Presence and Constant Illuminance Sensor (Model: SS3007.0101) completely resolves this critical industry failure point. By deploying sophisticated 24GHz live detection technology, this sensor does not merely look for sweeping physical movements; it continuously scans for the micro-biological signatures of human life, including subtle respiratory signals and micro-movements. Designed to form the sensory foundation of modern intelligent buildings, it guarantees absolute comfort, safety, and energy efficiency for corporate offices, high-stakes conference rooms, executive lounges, logistics warehouses, and transit stairwells.
Beyond its revolutionary presence detection, the SS3007.0101 serves as an autonomous environmental regulator. It natively integrates a high-precision constant illuminance sensor that evaluates ambient light levels in real-time. By communicating directly with KNX dimming actuators over the twisted-pair bus, it continuously modulates the artificial lighting load to match natural daylight ingress. This closed-loop system minimizes the load working cycle, significantly driving down electrical OPEX and ensuring compliance with stringent green building certifications (such as LEED and BREEAM). Proudly bearing full CE and KNX certifications, this hardware is rigorously tested and statistically verified for flawless parameterization within the latest ETS6.4.1 software framework (Validated for comprehensive deployment as of April 2026).
24GHz Millimeter-Wave Radar: The Mechanics of True Presence
Traditional Passive Infrared (PIR) relies on intersecting thermal zones, while standard 5.8GHz microwave sensors lack the resolution to detect minute shifts in spatial geometry. The SS3007.0101 elevates detection via its 24GHz high-frequency radar emitter. This technology accurately classifies spatial occupancy into three distinct biological tiers:
- Macro-Movement Tracking: Instantly triggers upon capturing standard walking or broad physical transitions as individuals enter the detection zone.
- Micro-Movement Resolution: Perfectly identifies fine motor functions, such as typing on a keyboard, writing on a notepad, or operating a mouse at a workstation.
- Respiratory Signal Capture: The defining feature of “True Presence.” In the complete absence of physical motion—such as an occupant meditating, sleeping, or reading intently—the radar detects the rhythmic expansion and contraction of the human chest cavity during breathing.
When installed at the optimal suction top mounting height of 2m to 3m, the sensor projects a highly concentrated spatial footprint. It provides a robust movement induction diameter/width of 4m to 8m, while maintaining a hyper-sensitive true presence (respiratory) diameter of 2m to 6m. This geometry ensures complete coverage of executive desks or boardroom tables without generating false positives from adjacent corridors.
Autonomous Constant Illuminance & Daylight Harvesting Engine
The SS3007.0101 acts as a localized energy management brain. Its onboard lux meter boasts an industrial-grade sensing range spanning from 1 lux up to an immense 60k lux. This wide spectrum allows the device to operate effectively in dimly lit basements as well as sun-drenched, glass-walled corporate atriums.
Through the ETS interface, integrators establish a specific work load intensity threshold (e.g., maintaining exactly 500 lux on a laboratory workbench). As the sun’s angle changes and natural light floods the room, the sensor calculates the variance and pushes proportional dimming values to the KNX LED drivers. This daylight harvesting cycle continuously dims the artificial lights to offset the free natural light, achieving massive energy conservation. Furthermore, the device supports internal or external illuminance value calibration and can be configured to cyclically broadcast these light readings to the central BMS for analytics and environmental reporting.
Complex KNX Logic, Distance Mapping, & Master-Slave Topologies
The firmware of the SS3007.0101 is heavily heavily optimized for B2B engineering flexibility, offering an extensive suite of programmable behaviors:
- Accurate Distance Sensitivity Mapping (Exclusive to SS3007): Unlike generic sensors with arbitrary sensitivity dials, the SS3007.0101 provides 10 levels of sensitivity that correspond directly to physical meter distances. Level 1 restricts detection to within 0.5 meters. Levels 2 through 10 map linearly from 1 to 9 meters (adding 1 meter per level). This allows field engineers to mathematically bound the detection zone, preventing the radar from penetrating through walls into adjacent offices.
- Independent Day/Night Profiles: Operational parameters can be bifurcated. An external KNX telegram can toggle the sensor between Day mode (aggressive daylight harvesting, 100% maximum output) and Night mode (triggering only a 15% dimming value for security patrols).
- Multi-Format Telemetry Output: Upon detecting biological presence, the sensor does not just send a simple ON command. It supports three distinct types of output data: 1-bit switching values, 1-byte granular dimming percentages, or 1-byte pre-programmed scene values.
- Dynamic Operating Modes: Supports Manual, Fully Automatic (ON with presence, OFF with vacancy), and Semi-Automatic modes. In Semi-Automatic, a user must physically press a wall switch to turn on the lights, but the sensor handles the automated shut-off once the room is vacated and the idle cycle expires—perfect for multimedia presentation rooms.
- Master-Slave Grid Efficiency: To blanket massive open-plan areas without bottlenecking KNX bus bandwidth, multiple SS3007 units can be networked. Slave units solely track biological signals and pass lightweight data flags to a single Master. The Master aggregates these inputs, monitors the lux levels, and sends unified commands to the lighting circuits.
Technical Parameters
| Parameter | Specification |
|---|---|
| KNX bus power supply | DC 21V~31V |
| Supply current | < 15mA |
| Power consumption | <450mW |
| Programming keys | Press the mask |
| Programming indicator light | LED |
| Maximum radius for micro motion detection | 4-5 meters, height 3 meters |
| Maximum radius for presence detection | 3-4 meters, height 3 meters |
| Sensitivity adjustable level | Level 10 |
| Sensitivity level corresponds to distance, And accurate distance is only supported by SS3007 | Level 1: Within 0.5 meters (inclusive); Levels 2 to 10 correspond to levels 1 to 9 meters (inclusive), with an additional 1 meter for each level added; |
| Mounting height | 2.5~3.0m, SS3007 up to 8m |
| installation | Suction top mount |
| The ambient light measuring range | 1 lux ~ 60k lux |
| Temperature measurement range | -20℃~55℃, ±1.5°C |
| Working temperature | -5°C ~+45°C |
| Long-term storage temperature | -25°C ~+55°C |
| Temperature in transit | -30°C~+70°C |
Global Procurement & System Integrator FAQ
Q1: How does the SS3007.0101’s 24GHz live detection outperform standard PIR sensors in commercial offices?
Answer: Standard PIR sensors require the occupant to cross thermal zones to register movement, which frequently leads to lights turning off when employees are sitting still at their desks. The SS3007.0101 utilizes 24GHz millimeter-wave radar to perform “Live Detection.” This high-frequency emission captures micro-movements (like typing) and even the respiratory signals (chest expansion during breathing) of completely stationary individuals. This guarantees true presence detection, eliminating the frustration of manual wave-to-activate interruptions during focused work.
Q2: What is the significance of the “Accurate Distance” sensitivity feature exclusive to the SS3007 model?
Answer: Microwave radar can penetrate non-metallic materials like glass and drywall, which can sometimes cause false triggers from adjacent hallways. The SS3007 specifically solves this through its accurate distance mapping protocol. Instead of an arbitrary sensitivity percentage, the 10 sensitivity levels correspond mathematically to physical meters. Level 1 confines detection to 0.5 meters. Levels 2 through 10 scale precisely from 1 to 9 meters. This empowers field engineers to tightly crop the detection bubble to match the exact dimensions of the room, entirely eliminating false triggering through walls.
Q3: How does the integrated Constant Illuminance sensor contribute to a building’s ROI?
Answer: The device features an onboard lux meter with an immense measuring range of 1 lux to 60k lux. By configuring a target work load intensity threshold via ETS, the sensor executes active daylight harvesting. It constantly measures the amount of natural sunlight entering the space and dynamically throttles the KNX dimming actuators to provide only the exact amount of artificial light necessary to meet the threshold. This closed-loop regulation minimizes the load working cycle, drastically lowering daily energy consumption and accelerating the Return on Investment (ROI) for the BMS infrastructure.
Q4: Is the hardware validated for compatibility with the latest ETS programming software?
Answer: Yes, absolute software stability is a cornerstone of our B2B offering. The SS3007.0101 is fully CE and KNX certified. More importantly, the product database is structurally verified for flawless integration within the latest ETS6.4.1 programming environment, with statistical validation current up to April 2026. Integrators can import the device, map complex logical group addresses, and deploy without encountering legacy architectural conflicts or application errors.
Q5: How does the Master-Slave networking function optimize bus communication in sprawling logistics warehouses?
Answer: In massive open-plan areas, allowing dozens of independent sensors to simultaneously transmit dimming commands will rapidly saturate the KNX bus bandwidth. By configuring the devices in a Master-Slave topology, the slave sensors are stripped of logic processing; they simply push a lightweight 1-bit biological presence flag to the assigned Master. The single Master node aggregates all spatial data, evaluates the room’s total lux reading, and transmits a unified 1-byte dimming or switching command to the actuators, keeping bus traffic incredibly lean and responsive.
Q6: What additional environmental telemetry does the SS3007.0101 provide to the wider BMS?
Answer: Beyond true presence and constant illuminance, the device acts as a decentralized climate node. It houses an integrated temperature measurement array capable of tracking local ambient temperatures from -20°C to 55°C (with an accuracy of ±1.5°C). Engineers can configure the sensor to periodically transmit these measured temperature values onto the bus, directly feeding HVAC fan-coil units or VAV boxes. This completely removes the procurement and installation costs associated with secondary wall-mounted thermostats.