Engineering Integration Highlights

  • ✔ Volumetric Microwave Presence Scanning
    Utilizes active high-frequency wave analysis to capture micro-movements like typing or breathing. Prevents false dropouts common with basic thermal sensors in commercial environments.
  • ✔ Target Pin-Type Antenna Profile
    Engineered for standard ceiling heights from 2m to 5m, delivering a wide horizontal footprint with a detection diameter of 6m to 15m. Fully adjustable across 10 distinct sensitivity levels.
  • ✔ Constant Light Daylight Harvesting
    Houses a precise onboard lux sensor (1 lux to 60k lux) that handles continuous constant illuminance dimming adjustments, maximizing green energy profiles and structural cost savings.
  • ✔ Certified ETS6.4.1 System Compatibility
    Fully CE and KNX certified hardware, with integration support verified for the latest ETS6.4.1 software framework (data verified up to April 2026) for secure, error-free field commissioning.
  • ✔ Adaptive Multi-Format Output Telemetry
    Highly versatile command options. The sensor outputs standard 1-bit switching data, granular 1-byte dimming values, or triggers complex 1-byte scene mappings upon presence detection.
  • ✔ Dual-Profile Day/Night Scheduling
    Supports independent functional configurations for daytime and nighttime shifts, switched instantly via incoming external bus objects to match custom facility hours.
  • ✔ Master-Slave Grid Topology Optimization
    Reduces bus load by pairing several slave nodes with a single master supervisor. Slaves pass simple 1-bit presence flags, protecting network bandwidth across large layouts.
  • ✔ Onboard HVAC Temperature Telemetry
    Features a built-in room temperature sensor operating from -20°C to 55°C, broadcasting data loops to the climate system and saving you the cost of extra wall-mounted hardware.
Download SIXINSMART KNX Microwave Presence / Constant Illuminance Sensor User Manual Download SIXINSMART KNX Microwave Presence / Constant Illuminance Sensor Technical Manual

Description

Commercial KNX Ceiling Mount Microwave Presence Sensor & Constant Illuminance Detector

Engineering high-efficiency commercial environments demands field infrastructure that reliably detects human presence while fine-tuning operational overhead. The KNX Ceiling Mount Microwave Presence / Constant Illuminance Sensor (Model: SS3004.0102) sets an industry benchmark for intelligent lighting control. Explicitly engineered for global smart building system integrators, electrical bulk wholesalers, and commercial procurement contractors, this native KNX network node delivers ultra-responsive volumetric scanning. Utilizing high-frequency wave analysis alongside precise illuminance evaluation, it automates commercial lighting and HVAC networks with absolute precision. It serves as the primary automation backbone for corporate open-plan offices, busy presentation halls, airport lounges, extended warehouse corridors, and complex high-traffic transit stairwells.

Built for continuous performance inside heavy enterprise bus lines, the SS3004.0102 holds official CE and KNX quality compliance certifications, guaranteeing multi-vendor ecosystem interoperability. To secure large-scale engineering investments, the underlying hardware architecture is fully tested and verified to support the industry’s newest deployment tool, operating flawlessly under the ETS6.4.1 software environment (Statistical system verification data complete and accurate up to April 2026). This robust configuration profile eliminates structural commissioning risks for local integration crews.

Advanced Micro-Motion Capture via High-Frequency Pin-Type Antenna Topology

Unlike standard thermal tracking sensors that require continuous cross-zone human movement to stay active, the SS3004.0102 integrates an expert-grade Pin-type Antenna (Needle Antenna) configuration. Operating via advanced microwave radar principles, it transmits low-power high-frequency waves into the architectural space and reads the phase shifts of the returning signals. This allows the sensor to detect micro-movements—such as an operator typing at a desk or a person breathing in a quiet conference room—even through light drywall or acoustic panels.

The pin-type antenna variant is geometrically optimized for typical office and hallway structures, supporting a dedicated installation height clearance of 2m to 5m while establishing a wide horizontal detection footprint spanning a diameter/width from 6m up to 15m. (For alternative high-bay implementations, our flat-antenna models cover a 2.5m to 12m vertical range with a 4m to 10m width matrix). To manage potential environmental noise caused by partition movement or mechanical duct vibrations, the sensor provides 10 levels of technical sensitivity adjustment in ETS, enabling precise boundary mapping by site engineers.

Precision Constant Illuminance Management & Continuous Daylight Harvesting

A standout B2B capability of the SS3004.0102 is its integrated Constant Illuminance (Constant Light) control loop—a premium engineering function built exclusively into the SS3003 and SS3004 series within our smart sensor lineup. Housing an onboard digital illuminance meter featuring an expansive tracking envelope from 1 lux up to 60k lux, the hardware handles proactive daylight harvesting. It constantly samples natural light levels coming through the windows and automatically modulates connected KNX dimming actuators. This smooth, progressive loop keeps work surfaces at a stable, pre-set brightness target, preventing over-lighting and drastically lowering a facility’s monthly energy expenses.

System layout engineers have full programmatic access to separate target illuminance thresholds for activating and deactivating circuits. They can establish specific load work intensity limits, perform internal or external light sensor calibrations, and set up the device to broadcast real-time lux values cyclically onto the bus for comprehensive central building management system (BMS) logging.

Adaptive Operational Modes & High-Efficiency Master-Slave Grid Topologies

To fit various building operating models, the underlying firmware supports multiple functional logic blocks:

  • Versatile Operational Logic: The device can switch seamlessly between Manual Mode, Full-Automatic Mode (turning on with motion, shutting down upon vacancy), and Semi-Automatic Mode (requiring an initial manual key press via wall switch, with the sensor handling the automated turn-off sequence). For dimmable infrastructure, it supports an elegant Standby Mode that lowers illumination to a safe orientation level during quiet periods rather than plunging corridors into total darkness.
  • Bifurcated Day/Night Profiles: The controller features independent logic branches for Day and Night. These are toggled dynamically across the network via an external KNX telegram (such as a time clock or light-level switch). This lets site managers run a high-output comfort profile during business hours and instantly swap to a restrictive, energy-saving profile at closing.
  • Scalable Master-Slave Clustering: Covering large, open commercial floors or complex logistics warehouses is easy thanks to the native master-slave network feature. Multiple slave units can be scattered across a zone to pass simple 1-bit motion alerts to a single master device. The master node handles all timing logic, samples ambient lux, and pushes compiled data—such as 1-bit switching data, 1-byte dimming percentages, or 1-byte pre-programmed scene values—straight to the actuators, keeping bus communication clear and fast.
  • Auxiliary Climate Telemetry: Adding extra value to the hardware, the SS3004.0102 includes a built-in room temperature sensor operating from -20°C to 55°C. It periodically broadcasts accurate local thermal data over the network to central HVAC systems, saving contractors the cost of buying and installing separate wall-mounted temperature probes.

Technical Parameters

Technical Parameter Product Specification
KNX bus power supply DC 21V~31V
Supply current < 10mA
Power consumption <300mW
Programming keys Press the mask or lens to assign physical address and program
Programming indicator light LED
Detection range The installation height, 2.5 m high sensitivity area 5~10 m diameter, low sensitivity area 10~ 14 m
Detection Angle Passive infrared : 130°; Microwave needle type antenna: 160° vertically;
Sensitivity adjustable level Level 10
Mounting height Passive infrared: 2 m to 4 m, 2.7 m recommended; Microwave needle type antenna: 2m~5m;
installation Suction top mount
The ambient light measuring range 1 lux 60k lux
Temperature measurement range -20℃~55℃, ±1.5°C
Working temperature -5°C~+45°C
Long-term storage temperature -25°C~+55°C
Temperature in transit -30°C~+70°C

Commercial Integration & Procurement FAQ

Q1: What structural advantages does the microwave presence technology inside the SS3004.0102 provide over basic PIR sensors?

Answer: While passive infrared (PIR) sensors rely strictly on surface temperature variations across focal zones, microwave radar tracking operates via active wave analysis. The SS3004.0102 transmits a low-power signal and monitors the frequency shifts of the reflected waves. This gives it the sensitivity to detect micro-movements, like stationary office personnel typing or reading, regardless of ambient room temperature. Furthermore, microwave signals can pass through thin interior glass partitions or acoustic drop ceilings, allowing you to hide the hardware above structural panels if required by architectural guidelines.

Q2: How does the constant light control block in the SS3004.0102 lower utility costs for building management?

Answer: The built-in constant light tracking engine runs an active daylight harvesting routine. By pairing the onboard light meter (1 lux to 60k lux) with a target brightness setpoint in ETS, the sensor continually adjusts connected dimming actuators. If natural sunlight fills the room, the sensor lowers the output of the light fixtures to bridge the gap. This prevents energy waste from over-lighting rooms that already have plenty of natural daylight, helping commercial facilities meet strict environmental compliance metrics.

Q3: What are the primary spatial installation differences between the pin-type antenna and the flat antenna variations?

Answer: The choice of antenna structural layout changes the sensor’s physical positioning profile. The SS3004.0102 features our custom Pin-type Antenna, which is designed for standard commercial environments with mounting heights between 2m and 5m, producing a wide detection circle with a diameter/width from 6m to 15m. Conversely, our alternative flat-antenna configuration is designed for high-bay logistics setups or tall atriums, supporting mounting heights from 2.5m to 12m with a targeted 4m to 10m footprint.

Q4: Is the SS3004.0102 verified for use with the newest commercial KNX software platforms?

Answer: Yes. The SS3004.0102 holds verified CE and KNX standard certification profiles. The product’s application files are fully optimized for seamless integration under the newest ETS6.4.1 programming framework, with statistical validation logs current up to April 2026. This allows installation technicians to confidently map group addresses, adjust object blocking features, and configure data parameters without dealing with product database file errors.

Q5: Can the built-in master-slave clustering feature optimize bus traffic on extensive project installations?

Answer: Yes, this is a major advantage for large-scale floor plans. Having multiple sensors independently pushing commands can flood a KNX line with unnecessary group object traffic. With the master-slave feature, you can set one device as the Master logic node and configure peripheral units as Slaves. The slave sensors simply send a small 1-bit presence flag to the Master when they detect motion. The Master processes the data, tracks light thresholds, and handles the final execution commands, significantly reducing network overhead.

Q6: How do independent Day/Night profiles change the sensor’s control data outputs?

Answer: The device allows you to build separate behavioral routines for day and night operations, switched via an external bus object like a central clock or building calendar. For example, a motion trigger during the day can be set to send a 1-bit switching command for 100% lighting, while the same trigger at night can fire a 1-byte dimming command for 15% safety lighting or activate a custom security scene.