Commercial-Grade KNX Ceiling Mount Passive Infrared Presence Detector

In the rapidly expanding landscape of intelligent building automation, reliable occupancy detection is the cornerstone of energy conservation and occupant comfort. The KNX Ceiling Mount Passive Infrared (PIR) Presence Detector (Model: SS3001.0101) is explicitly engineered to meet the rigorous demands of global system integrators, electrical wholesalers, and commercial engineering contractors. By accurately capturing human body thermal motion and seamlessly integrating with the environmental illumination context, this advanced KNX PIR motion sensor automates load control across a multitude of architectural spaces. It is the premier sensing solution for modern offices, executive conference rooms, high-traffic corridors, lounges, and stairwells.

Designed to operate natively on the standardized KNX bus, the SS3001.0101 eliminates the complexities of proprietary bridging. It is strictly CE and KNX certified, assuring electrical contractors of its uncompromised safety and interoperability on a global scale. Furthermore, to safeguard your large-scale infrastructure investments, this hardware is structurally verified and fully compatible with the latest ETS6.4.1 engineering software (Statistical compatibility data current and verified as of April 2026). This guarantees that your procurement today will integrate flawlessly with tomorrow’s secure KNX topologies.

Precision Passive Infrared (PIR) Detection Architecture

The SS3001.0101 operates on highly refined passive infrared principles, detecting the subtle thermal signatures emitted by the human body against the ambient background temperature. It features a meticulously designed Fresnel lens that provides a comprehensive 130° detection angle. When installed at the recommended height of 2.7 meters (with a supported range of 2m to 4m), the detector establishes a highly sensitive central monitoring area spanning 5 to 10 meters in diameter, perfect for detecting micro-movements such as typing at a workstation. The secondary low-sensitivity peripheral zone extends from 10 to 14 meters, capturing macro-movements like walking, ensuring a seamless handover as occupants move through expansive commercial spaces.

To completely eliminate false triggers caused by HVAC drafts, sudden sunlight, or localized thermal events, system integrators can utilize the ETS software to fine-tune the sensor’s responsiveness across 10 distinct sensitivity levels. This localized calibration ensures that the detector responds exclusively to genuine human presence.

Master-Slave Network Topology for Expansive Areas

One of the most significant challenges in commercial lighting automation is managing massive open-plan offices or extended logistics corridors without overwhelming the KNX bus with redundant data. The SS3001.0101 elegantly solves this through its native Master-Slave Network Function.

In this topology, a single detector is parameterized as the “Master,” responsible for executing all complex logic, evaluating light thresholds, and maintaining the time delays. Multiple “Slave” detectors are deployed throughout the extended zone. These slaves act purely as thermal sensory extensions, transmitting a simple, lightweight occupancy telegram to the Master. The Master aggregates this data; if any node detects presence, the Master sustains the lighting load. It can output three distinct types of data to the actuators: a 1-bit switching value (ON/OFF), a 1-byte dimming value (e.g., transition to 75% brightness), or a 1-byte scene value to trigger complex room states. This architecture drastically simplifies programming and preserves crucial bus bandwidth.

Dynamic Control Modes and Environmental Sensing

The functional versatility of the SS3001.0101 allows it to adapt to the specific operational philosophy of any facility:

  • Flexible Working Modes: Integrators can select Fully Automatic Mode for areas like hallways where lights must trigger instantly upon entry. For presentation rooms, the Semi-Automatic Mode is ideal; it requires a manual button press to turn lights on, but the detector automatically switches them off once the room is vacated and the idle cycle expires, preventing energy waste. A Standby Mode is also available to dim lights to a safe orientation level rather than switching them completely off.
  • Independent Day/Night Profiles: Lighting requirements change dramatically after sunset. This detector allows engineers to configure entirely independent logic for Day and Night, switchable via an external KNX telegram. A corridor can illuminate to 100% during business hours, but only trigger to a soft 20% dimming value during night shifts to avoid visual glare.
  • Broad Illuminance Sensing: Featuring an onboard light meter with a range of 1 lux to 60k lux, the device allows for strict load work intensity thresholds. If natural daylight is sufficient, the detector will block the “ON” command, maximizing energy savings. The illuminance values can be calibrated (internally or externally) and broadcast cyclically to the bus.
  • Integrated Temperature Measurement: Providing profound value beyond lighting, the SS3001.0101 continuously measures ambient temperature (-20°C to 55°C) and transmits these values periodically. This feeds critical localized thermal data to the KNX HVAC system, often eliminating the need for standalone wall-mounted thermostats.

Technical Parameters

Parameter Specification
KNX bus power supply DC 21V~31V
Supply current < 10mA
Power consumption <300mW
Programming keys Press the mask or lens to assign physical address and program
Programming indicator light LED
Detection range The installation height, 2.5 m high sensitivity area 5~10 m diameter, low sensitivity area 10~ 14 m
Detection Angle Passive infrared : 130°; Microwave needle type antenna: 160° vertically;
Sensitivity adjustable level Level 10
Mounting height Passive infrared: 2 m to 4 m, 2.7 m recommended; Microwave needle type antenna: 2m~5m;
installation Suction top mount
The ambient light measuring range 1 lux 60k lux
Temperature measurement range -20℃~55℃, ±1.5°C
Working temperature -5°C~+45°C
Long-term storage temperature -25°C~+55°C
Temperature in transit -30°C~+70°C

Global B2B FAQ: Integration & Engineering Support

Q1: What makes the Passive Infrared (PIR) technology in the SS3001.0101 ideal for commercial office spaces?

Answer: The PIR technology in the SS3001.0101 detects the movement of heat signatures across its multi-segmented Fresnel lens. This makes it highly accurate for identifying human presence in defined, unobstructed spaces like offices and meeting rooms. Unlike active microwave sensors, PIR does not penetrate walls or glass, meaning movement in a bustling hallway will not falsely trigger the lights inside a closed glass-partitioned executive office. This spatial boundary enforcement is critical for localized energy efficiency.

Q2: How does the Semi-Automatic mode enhance energy savings in conference rooms?

Answer: In conference rooms equipped with projectors, users often want lights off even when people are present. In Semi-Automatic mode, the SS3001.0101 will not turn the lights on automatically when someone walks in; the user must press a KNX wall switch. However, the detector continuously monitors occupancy. Once the meeting ends and the room is vacated, the detector will automatically turn the lights off after the idle cycle expires. This prevents lights from being left on overnight, maximizing energy conservation while respecting user intent.

Q3: How do electrical contractors benefit from the Master-Slave networking capability?

Answer: For extensive areas like airport lounges or long hotel corridors, a single detector’s range is insufficient. Instead of programming complex logic for every single sensor, contractors can set one unit as the Master and the rest as Slaves. Slaves simply push a lightweight “presence detected” telegram to the Master. The Master handles all the heavy lifting—evaluating light levels, timers, and outputting the final command to the actuators. This architecture drastically reduces commissioning time in ETS and ensures low data congestion on the KNX bus.

Q4: Is the SS3001.0101 guaranteed to work with the newest KNX project software?

Answer: Yes. For global wholesalers and system integrators, software longevity is a primary concern. The SS3001.0101 is fully certified and verified for seamless compatibility with the ETS6.4.1 software framework (confirmed as of April 2026). You can confidently import the product database into your newest projects without fearing deprecated group objects or legacy communication errors.

Q5: Can the built-in temperature sensor replace a traditional wall thermostat?

Answer: In many commercial applications, yes. The SS3001.0101 features an integrated temperature sensor capable of measuring from -20°C to 55°C with an accuracy of ±1.5°C. By configuring the detector to periodically broadcast this temperature value onto the KNX bus, the central HVAC controller can use this data for climate regulation. This eliminates the material and labor costs of installing separate temperature probes throughout the ceiling.

Q6: How do Day/Night profiles affect the output data of the detector?

Answer: Through ETS, integrators can set two completely different behavioral parameters. When the central building timer sends a “Night” telegram, the detector instantly switches profiles. For example, during the day, motion might trigger a switching value of “ON” (100% brightness). At night, the same motion might trigger a dimming value of “20%” or a specific Scene value to provide safe navigation lighting without blinding the occupants or wasting heavy load power.