Description
Enterprise KNX Dual-Tech Presence & Constant Illuminance Detector
The ultimate synergy of 24GHz Microwave and Passive Infrared (PIR) technologies. Designed for global system integrators and electrical wholesalers outfitting premium smart commercial buildings.
In the demanding landscape of modern commercial building automation, relying on a single sensing technology often leads to compromised user experiences—such as lights turning off when employees sit still, or false triggers from HVAC air currents. The SIXIN KNX Occupancy & Constant Illuminance Sensor + Passive Infrared (PIR) Dual-Detection Sensor (Model: SS3008.0101) flawlessly resolves these critical engineering challenges. By fusing the macro-movement tracking of high-density PIR with the micro-movement and respiratory detection capabilities of 24GHz microwave radar, this sensor achieves absolute, infallible human presence detection.
Built exclusively for B2B procurement, this KNX dual-tech presence detector is the foundational node for energy-saving, comfortable, and secure intelligent infrastructures. It thrives in complex applications including executive boardrooms, open-plan offices, quiet lounges, extended corridors, logistics warehouses, and enclosed stairwells. Fully certified with CE and KNX marks, the hardware architecture is deeply optimized and statistically verified for flawless integration with the latest ETS6.4.1 software environment (Verified comprehensive compatibility as of April 2026). This guarantees your field technicians a smooth, risk-free commissioning process free from legacy database conflicts.
The Dual-Detection Advantage: PIR Meets 24GHz Microwave
Standalone PIR sensors require occupants to cross thermal zones, while standalone microwave sensors can sometimes penetrate thin walls and cause false triggers from adjacent rooms. The SS3008.0101 harmonizes both technologies to create a hyper-accurate sensing umbrella:
- PIR Macro-Tracking: Instantly captures the thermal signature of walking individuals as they enter the room, triggering an immediate, reliable lighting response without looking through physical boundaries.
- 24GHz Microwave Micro-Tracking: Once inside, the ultra-high-frequency radar takes over to monitor micro-movements (typing, writing) and human respiratory signals (chest expansion). This ensures lights never plunge occupants into darkness during focused, stationary work.
- Synergistic Logic: Field engineers can configure the ETS logic so that both sensors must detect presence to trigger the initial ON command (eliminating false alarms), but either sensor can sustain the active state, maximizing occupant comfort.
Autonomous Constant Illuminance & Daylight Harvesting
Energy efficiency is the primary driver for commercial KNX adoptions. The SS3008.0101 features an integrated lux meter with an expansive sensing range of 1 lux to 60k lux. This allows the sensor to execute highly accurate daylight harvesting. By continuously evaluating the natural sunlight entering an office or corridor, the sensor dynamically regulates connected KNX LED dimming actuators. It seamlessly bridges the gap between natural light and the architect’s specified work load intensity threshold (e.g., maintaining a constant 500 lux at desk level).
This closed-loop automated control minimizes the artificial load working cycle, dramatically cutting electrical OPEX and supporting prestigious green building certifications. System engineers can perform internal or external illuminance calibration and set the device to periodically transmit the current lux value to the central Building Management System (BMS) for environmental logging.
Advanced KNX Network Topology & Master-Slave Clustering
The SS3008.0101 provides an extensive array of programmable ETS parameters tailored for complex wholesale integrator requirements:
- Master-Slave Network Function: Scale effortlessly across massive open-plan offices. Configure one primary unit as the logic Master and multiple surrounding units as Slaves. Slaves pass lightweight presence flags to the Master, which evaluates total room occupancy and ambient light before pushing a unified command to the actuators. This slashes KNX bus data congestion.
- Dynamic Operating Modes: Choose between Manual, Fully Automatic, and Semi-Automatic. The semi-automatic mode is ideal for multimedia rooms—requiring a manual wall-switch press to turn lights on, while the sensor autonomously handles the turn-off sequence once the room is vacated and the idle cycle expires.
- Multi-Format Output Topologies: Supports three types of output data upon motion detection: standard 1-bit switching values, precise 1-byte dimming percentages, and complex 1-byte scene values (e.g., triggering a “Meeting” scene that lowers blinds and adjusts HVAC simultaneously).
- Independent Day/Night Profiles: Allows distinct operational behaviors for daytime and nighttime shifts. An external KNX telegram can toggle these modes, switching from 100% constant light control during the day to a subdued 20% standby dimming mode at night.
- Infrared Remote Control & Ambient Temperature: Features support for IR remote control to seamlessly activate programming modes without dismantling the ceiling. Additionally, it periodically transmits measured ambient temperature (-20°C to 55°C) to the bus, driving local HVAC fan-coils directly.
Technical Parameters
| Parameter | Specification |
|---|---|
| KNX bus power supply | DC 21V~31V |
| Supply current | < 20mA |
| Power consumption | <600mW |
| Programming keys | Press the mask |
| Programming indicator light | LED |
| PIR detection range | Installation height of 2.5m, diameter of motion detection high sensitivity area of 5-10m; |
| Microwave detection range | Installation height of 2.5m, human body sitting detection diameter of 4m, motion detection direct 8m, accuracy ±0.2m |
| Sensitivity adjustable level | Level 10 |
| Mounting height | 2.0~4.0m |
| installation | Suction top mount |
| The ambient light measuring range | 1 lux~60k lux |
| Temperature measurement range | -20℃~55℃ ±1.5℃ |
| Working temperature | -5℃~+45℃ |
| Long-term storage temperature | -25℃~+55℃ |
| Temperature in transit | -30℃~+70℃ |
Global Procurement & System Integration FAQ
Q1: Why should an engineering contractor choose a Dual-Tech (PIR + Microwave) sensor over standalone technology?
Answer: Standalone PIR sensors are excellent at detecting macro-movements (like walking) but fail to detect stationary occupants working quietly. Standalone microwave sensors detect micro-movements flawlessly but can penetrate walls, causing false triggers from people walking in adjacent hallways. The SS3008.0101 dual-tech sensor combines both. It uses PIR to ensure motion is strictly within the room boundaries before turning lights on, and uses 24GHz microwave to continuously monitor human breathing and micro-movements to keep the lights on. This synergy guarantees zero false triggers and absolute presence reliability.
Q2: How does the master-slave network function reduce KNX bus congestion in large warehouses or offices?
Answer: In expansive architectural layouts, installing dozens of autonomous sensors creates immense data traffic as each unit continuously transmits dimming commands. By configuring the system in a master-slave topology, all slave sensors are programmed simply to detect presence and pass a lightweight 1-bit flag to a central master sensor. The master unit alone processes the complex logic—such as evaluating the ambient illuminance (1 lux ~ 60k lux), calculating idle cycles, and dispatching a single, unified command to the lighting actuators. This drastically streamlines ETS commissioning and preserves bus bandwidth.
Q3: Is the SS3008.0101 verified to operate securely with the newest ETS programming software?
Answer: Yes, system longevity is fully guaranteed for wholesale distributors. The hardware holds official CE and KNX certifications. Furthermore, its product application database (.knxprod) is rigorously tested and statistically verified for flawless, stable integration within the latest ETS6.4.1 programming framework (Data current up to April 2026). Integrators will not encounter legacy architectural conflicts when mapping group objects or setting up secure KNX topologies.
Q4: What role does the built-in ambient temperature measurement play in building automation?
Answer: The SS3008.0101 is more than a lighting controller; it is a decentralized climate node. It houses an integrated thermal sensor capable of tracking ambient temperatures from -20℃ to 55℃. By configuring the device to cyclically transmit this temperature data to the KNX bus, the central HVAC system can use these readings to regulate local fan-coil units or VAV boxes. This eliminates the material and labor costs associated with installing separate wall-mounted thermostats throughout the facility.
Q5: Can the device’s behavior be altered between working hours and after-hours security patrols?
Answer: Absolutely. The sensor supports independently configured day/night control modes. A central KNX clock or security panel can send a telegram to toggle the sensor’s profile. During the day, motion might trigger full 100% constant illuminance control. At night, the exact same motion could trigger a subdued 15% dimming value (standby mode) to provide safe orientation lighting without drawing massive electrical loads or causing visual shock.