Wholesale KNX Ceiling Mount Passive Infrared Presence & Constant Light Detector SS3003.0101 | Smart Building Automation

Download KNX Ceiling Mount Passive Infrared Presence / Constant Illuminance Detector User Manual Download KNX Ceiling Mount Passive Infrared Presence / Constant Illuminance Detector Technical Manual

Description

Commercial-Grade KNX Ceiling Mount Passive Infrared Presence & Constant Light Detector

In modern commercial infrastructure, the optimization of lighting control is paramount for achieving rigorous energy efficiency certifications (such as LEED or BREEAM) while maintaining absolute occupant comfort. The KNX Ceiling Mount Passive Infrared (PIR) Presence and Constant Light Detector (Model: SS3003.0101) is explicitly engineered for wholesale distribution to system integrators, electrical contractors, and building automation engineers. This highly sensitive KNX-certified node seamlessly detects human body motion and continuously monitors environmental illumination to execute automated, intelligent load control. Designed for rapid suction top mount installation, it serves as the foundational sensory layer for offices, conference rooms, high-traffic corridors, expansive warehouses, and stairwells.

Operating natively on the KNX bus, this detector eliminates the need for proprietary gateways. It proudly carries both CE and KNX certifications, ensuring uncompromised compliance with global electrical safety and interoperability standards. To future-proof your large-scale deployments, the SS3003.0101 is fully optimized and structurally verified for compatibility with the latest ETS6.4.1 software (Verified statistical compatibility as of April 2026). Integrators can reliably assign physical addresses and program complex logic arrays knowing the hardware is fully aligned with the current apex of KNX engineering software.

Advanced Constant Light Control & Illumination Sensing

The SS3003.0101 distinguishes itself from basic motion sensors through its integrated Constant Light Function. Utilizing a highly calibrated internal lux meter with an immense measuring range of 1 lux to 60k lux, the device continuously evaluates the contribution of natural daylight entering a space. As daylight increases, the detector automatically commands the KNX dimming actuators to reduce the artificial lighting output, maintaining a strictly regulated, constant lux level on the work surface. This closed-loop regulation prevents over-illumination, drastically cutting energy consumption without requiring manual user intervention.

To ensure absolute precision across diverse architectural environments, the illuminance values can undergo either external or internal calibration. The device also supports a periodic illumination value output function, pushing real-time lux data to the KNX bus for central BMS (Building Management System) logging or secondary logic triggers.

Granular Motion Detection and Master-Slave Topology

Equipped with a highly refined passive infrared lens, the detector boasts a 130° detection angle. Depending on the installation height (recommended at 2.7m, capable of 2m to 5m), it covers a high-sensitivity central area of 5 to 10 meters in diameter, extending to a 10 to 14-meter low-sensitivity peripheral zone. Engineers can fine-tune the responsiveness using 10 distinct motion detection sensitivity levels via ETS, filtering out false triggers caused by HVAC drafts or minor mechanical vibrations.

For expansive architectural spaces such as open-plan offices or long logistical corridors, the SS3003.0101 supports a robust Master-Slave Network Function. Multiple slave detectors can be wired along the bus to expand the detection footprint seamlessly. The master unit aggregates the motion data from all connected slaves and executes the control logic, possessing three distinct types of output data: switching values, dimming values, and specific scene values. This synchronized topology minimizes bus traffic and simplifies the programming matrix.

Dynamic Working Modes and Logic Parameters

The detector adapts to the operational rhythm of the building through highly configurable working modes:

  • Automated & Semi-Automated Modes: Configure the sensor to automatically switch lights on upon presence and off upon vacancy, or require a manual push-button activation (semi-automatic) while retaining the automated switch-off logic based on a programmed idle cycle.
  • Independent Day/Night Control: Behavior profiles can be configured independently for day and night operations, switchable via an external KNX telegram. This allows for bright, constant light regulation during the day, and subdued, 20% orientation lighting triggered by motion at night.
  • Standby Mode: In light output configurations, the sensor supports a standby mode, maintaining a baseline illumination rather than plunging a space into total darkness.
  • Temperature Measurement: The device periodically sends measured ambient temperature values (-20°C to 55°C) to the bus, providing localized climate data to the HVAC control system without requiring additional thermostats.

Technical Parameters

Parameter Specification
KNX bus power supply DC 21V~31V
Supply current < 10mA
Power consumption <300mW
Programming keys Press the mask or lens to assign physical address and program
Programming indicator light LED
Detection range The installation height, 2.5 m high sensitivity area 5~10 m diameter, low sensitivity area 10~ 14 m
Detection Angle Passive infrared : 130°; Microwave needle type antenna: 160° vertically;
Sensitivity adjustable level Level 10
Mounting height Passive infrared: 2 m to 4 m, 2.7 m recommended; Microwave needle type antenna: 2m~5m;
installation Suction top mount
The ambient light measuring range 1 lux 60k lux
Temperature measurement range -20℃~55℃, ±1.5°C
Working temperature -5°C~+45°C
Long-term storage temperature -25°C~+55 °C
Temperature in transit -30°C~+70°C

Technical Support & B2B Integration FAQ

Q1: How does the master-slave network function operate in a large open-plan office?

Answer: In extensive zones where a single detector’s 10-14m coverage is insufficient, system integrators can deploy multiple SS3003.0101 units utilizing the master-slave architecture. Only the designated “Master” detector is programmed with the complex control logic (illuminance thresholds, time delays, and constant light regulation). The “Slave” units are configured strictly to detect motion and transmit a simple presence telegram to the Master over the KNX bus. The Master aggregates these signals; as long as any slave detects motion, the Master keeps the lighting active. This drastically reduces bus load and simplifies ETS commissioning for commercial contractors.

Q2: What is the primary advantage of the Constant Light Control function for green building certifications?

Answer: Green building standards heavily penalize artificial lighting in areas with adequate daylight. The SS3003.0101 incorporates a closed-loop constant light algorithm. You establish a target lux value (e.g., 500 lux for a workstation). The detector’s onboard light sensor continuously measures the ambient light. If natural sunlight provides 300 lux, the detector calculates the deficit and instructs the KNX dimming actuators to output exactly the necessary capacity to bridge the gap to 500 lux. As the sun sets, artificial lighting smoothly increases. This yields substantial energy reductions, directly contributing to LEED points and lowering operational OPEX for facility management.

Q3: Can the detector output different control data types depending on the project requirement?

Answer: Yes, flexibility is a core design principle. The motion monitoring function supports three distinct types of output data over the bus. It can send a standard 1-bit switching value (ON/OFF), a 1-byte dimming value (e.g., commanding lights to transition directly to 75% brightness), or a 1-byte scene value (triggering a pre-programmed “Presentation Mode” across actuators, blinds, and HVAC). This versatility makes it suitable for simple corridor lighting or complex boardroom automation.

Q4: Is the hardware compatible with the latest iteration of the ETS software?

Answer: Absolutely. The SS3003.0101 is fully certified and strictly compatible with the latest ETS6.4.1 software framework (verified compatibility data accurate through April 2026). Wholesalers can confidently supply this hardware to integrators utilizing modern KNX secure topologies, ensuring smooth database imports and reliable parameterization without legacy software conflicts.

Q5: How does the detector handle false triggers caused by pets, thermal drafts, or non-human movement?

Answer: To guarantee operational reliability, the SS3003.0101 allows engineers to select from 10 distinct motion detection sensitivity levels. In environments prone to thermal interference (like near HVAC vents) or mechanical vibrations, the sensitivity can be lowered to require a larger infrared signature or more definitive movement before triggering an occupancy state. This prevents nuisance switching and phantom power consumption.

Q6: How do the Day/Night control modes differ in practical application?

Answer: The Day/Night control profiles are independently configured within the ETS parameters and can be toggled via an external KNX object (such as a central building clock or weather station). In a hospital corridor, the “Day” mode might trigger lights to 100% brightness upon motion. Upon receiving the “Night” telegram, the detector instantly switches profiles, ensuring that any detected motion only triggers the lights to a comfortable 15% dimming value, preventing visual shock to patients while ensuring safe navigation.